1-1 ACTIVE/PASSIVE ARMING:
When active arming is selected, the system will only arm when the
remote is used. When set to passive, the system will arm automatically 30 seconds after the last door
is closed. To alert the consumer of passive arming, the siren will chirp 20 seconds after the door is
closed. This provides the consumer with an audible indication prior to the system actually arming. At
the 30 second mark, the system will arm but the siren will not chirp.
1-2 Chirps ON/OFF:
This feature controls the chirps that confirm the arming and disarming of the system.
1-3 IGNITION CONTROLLED DOOR LOCKS ON/OFF:
When turned on, the doors will lock
three seconds after the ignition is turned on and unlock when the ignition is turned off. The Pro
Security Programmer will display separate steps for ignition lock and ignition unlock. They can be pro-
grammed on or off independently.
1-4 ACTIVE/PASSIVE LOCKING:
If passive arming is selected in step 1-1, then the system can be pro-
grammed to either lock the doors when passive arming occurs, or only lock the doors when the system
is armed via the remote. Active locking means the system will not lock the doors when it passively arms.
Passive locking means that the system will lock the doors when it passively arms.
N
NO
OTTEE:: Remember, when passive arming is selected, the unit will chirp 20 seconds after the last door is
closed. The system does not actually arm or lock the doors until 30 seconds after the door has been
closed.
1-5 PANIC WITH IGNITION ON:
This step controls whether or not the panic mode is available with the
ignition on. In some states, there are laws prohibiting a siren from sounding in a moving vehicle. This
feature makes the system compliant with these regulations.
1-6 DOOR LOCK PULSE DURATION:
Some European vehicles, such as Mercedes-Benz and Audi,
require longer lock and unlock pulses to operate the vacuum pump. Programming the system to pro-
vide 3.5 second pulses, will accommodate the door lock interface in these vehicles. The default setting
is 0.8 second door lock pulses.
1-7 FORCED PASSIVE ARMING ON/OFF:
To use this feature, passive arming must be selected in step
1-1. When turned on, forced passive arming will ensure that the system will passively arm, even if a
zone is left open or invalid. Forced passive arming occurs one hour after the ignition is turned off.
1-8 AUTOMATIC ENGINE DISABLE ON/OFF:
Automatic Engine Disable is a full-time, passive starter
disable that works independently of the security system. When turned on, the orange, ground-when-
armed output (H1/1) will go active 30 seconds after the ignition is turned off. The LED will flash at half