clare ClareOne CLR-C1-ODDW Скачать руководство пользователя страница 1

© 18AUG20 Clare Controls, LLC. 

1 / 4 

DOC ID 

– 1947 • Rev 02 

 

ClareOne Outdoor Sensor Installation Sheet

 

Last modified:

 08/18/20 

Model number:

 CLR-C1-ODDW 

Description 

The CLR-C1-ODDW is a supervised wireless sensor that 
detects the opening and closing of doors, windows, gates, 
garage doors, etc. in extreme environments (-32° to 120°F  
(-35.6° to 49°C)). The sensor is constructed with a water-tight 
internal gasket to keep the sensor dry and protected from the 
elements. The unique design allows for outdoor mounting. The 
sensor and magnet are mounted using screws (included) or 
straps to secure the sensor to a post. 

When activated, the sensor transmits an open (trip) or close 
(restore) signal to the panel. The sensor transmits supervisory, 
tamper, and low battery (as needed) to the ClareOne panel. 
The sensor is powered by (2) replaceable CR 2032, 3-VDC, 
Lithium batteries. 

Installation  

Follow the installation guidelines.  

 

Mount the sensor on a non-moving frame or post, allowing 
the magnet to move activating the sensor. 

 

Mount sensors at least 5 inches above the ground to avoid 
damaging them.  

 

The sensors can be mounted to either wood or metallic 
surfaces.  

 

Mounting the sensor on metal can affect the transmitting 
range and magnet gap performance. Test the sensor from 
the desired location using the installer sensor test before 
permanently mounting. (This test can be performed using 

the ClareOne panel’s sensors testing feature. Settings > 
User/Installer Settings > System Tests > Sensor Test)  

 

The magnet should be 

mounted within 7/8” for wood or 

1/2” for metal installations. Based on the magnet mount 
spacing, direction of operation, and material of the 
mounting surface, the gap for opening varies 

between 1/8” 

and 1 ¾”. Desired operation should be checked before 
permanent installation.  

 

After mounting the sensor, re-test the sensor using the 
procedure in the section “Testing the sensor.” 

Mounting the sensor  

Mount the sensor using the supplied mounting screws or 
straps (not included).  

To mount the sensor using mounting screws:  

1.  Remove the cover screw from the sensor.  

2.  Mount the sensor using 3 mounting screws and the 

magnet using 2.  

 

3.  Mount the magnet into the desired location making sure 

the magnet alignment mark lines up with the sensor mark.  

 