Clare Controls CLIQ.lite Controller Скачать руководство пользователя страница 4

4 / 4 

 

Doc ID - 724 • REV 07 

Powering the CLIQ.lite 

Plugging in the power adapter automatically turns on the 

CLIQ.lite and starts the boot process.  

To connect power to the CLIQ.lite: 

1.  Plug one end of the power adapter into a power receptacle 

on the back of the CLIQ.lite labeled “12vdc.” See  

Figure 3, item 9. 

2.  Check the LED on the front of the CLIQ.lite. It illuminates 

purple when booting and blue when running normally. See 

Figure 2, item 1. 

Time, date, and time zone 

Your CLIQ.lite controller automatically detects and sets its 

time, date, and time zone when you connect it to your data 

network. CLIQ.lite uses NTP and synchronizes the date and 

time at boot up and periodically throughout the day. 

Configure, test, and deploy a project 

Refer to the Clare Controls Knowledge Base

 

Fusion Help

 for 

instructions on creating, testing, and deploying a project. When 

you deploy the project from Fusion, it will deploy to the 

CLIQ.lite.  

Adding the rubber foot covers 

To prevent the unit from sliding, use the four rubber foot covers 

included with your CLIQ.lite.  

To add the rubber feet: 

  Peel each foot cover from the paper backing and place 

one on each foot on the bottom of the CLIQ.lite. 

Upgrading your CLIQ.lite license 

With a simple license update, you can upgrade your CLIQ.lite 

to have the same unlimited functions as a CLIQ.host. To 

upgrade your license, contact our Technical Support group at 

the numbers listed in the “Contact information” section. Before 

calling, be sure you have the following information available. 

  License key number  

  UUID (listed on the bottom of the unit) 

  Dealer name and address 

Regulatory information 

 
Manufacturer 

Clare Controls, Inc. 

7519 Pennsylvania Ave, Suite 104 

Sarasota, FL 34243 

FCC compliance 

This device complies with part 15 of the FCC 

Rules. Operation is subject to the following two 

conditions: (1) This device may not cause harmful 

interference, and (2) this device must accept any 

interference received, including interference that 

may cause undesired operation. 

 

Specifications 

 

Applications supported 

Audio zones 

4 zones 

Audio streams 

Lighting 

10 circuits 

Security 

1 partition, 8 zones 

Thermostats 

Cameras 

Pool spa 

Not supported 

Entertainment 

I/O ports 

RS-232 [1] 

IR outputs 

6 (2 pins per IR) 

USB [2] 

I/O 

4 (8 pins) 

CobraNet 

Ethernet 

Relay 

6 pin, (2 normally open, 2 normally closed) 

General 

Processor 

Freescale iMX6 

Operating system 

Linux 

Memory 

2 GB DRAM, 1 GB NAND Flash 

Power 

8.4 W (700 mA at 12 VDC)

 

Operating temperature 

41 to 113°F (5 to 45°C) 

Relative humidity 

10 to 90%, non-condensing 

Dimensions (W × H × D)  1.3 × 8 × 6 in. (3.3 × 20.32 × 15.24 cm) 

[1] CLIQ.lite units support RS232 speeds of 300 baud and higher. 
[2] CLIQ.lite units marked Rev C or higher use both USB ports. Units 

marked Rev B or lower, or with a numerical revision level, are use the 

top USB port only. See the label on the bottom of the unit to 

determine its revision level. 

Contact information 

Clare Controls, Inc. 

7519 Pennsylvania Ave, Suite 104 

Sarasota, FL 34243 

Support: 941.404.1072 

Fax: 941.870.9646 

http://support.clarecontrols.com 

www.clarecontrols.com 
 

Отзывы: