background image

P.12

P.13

4. Use

3.5 Initial start-up

       Do not switch on the electric power at this time!

      

1.  To purge the instantaneous water heater, open the hot water tap and wait until the water emerges free 

of air bubbles.

2.  In order to obtain an optimum water jet at low flow rates, screw the enclosed special tap aerator into 

the tap outlet.

3.  Switch on the electric power.

4.  Adapt the water flow if necessary, if for example the temperature is not reached. The procedure is 

described in the chapter “Use”.

5.  Explain the functions and use of the instantaneous water heater to the user and hand over these 

operating instructions to the user for information and future reference.

6.  Register the appliance with the customer service department using the registration card or online at 

www.germanpool.com.

3.Installation

As soon as the hot water tap is opened, the instantaneous water heater switches on automatically. Close the 

tap and the appliance switches off automatically again.

4.1 Rating plate cover

On the inner part of the cover you can find the name of the application type (1), as well as the serial number 

(2) and the article number (3).

4.1.1 Removing the cove

r

Under this cover, the rating plate and the hood screw are located.

1. Push the cover at the corrugation towards the wall bracket.

2. At the rear corners press the cover down until the front edge lifts.

3. Remove the cover by pulling forward.

1

2

AAAA

Gerät an Schutzleiter

anschließen!

Appliance must be earthed!

BBBB

CCCC

3

4.1.2 Replacing the cover

1. Push the cover flat towards the wall bracket under the edges of the water connections.

2. Press down the front edge of the cover and push it forward again at the rear edge until it fits.

Содержание German pool GPI-M3

Страница 1: ...nty information carefully before use and keep them handy for future reference Online Warranty Registration U S E R M A N U A L GPI M3 Instantaneous Electric Water Heater WH GPI M3 M 18 1 Printed in Ge...

Страница 2: ...lation of the appliance and for the end user The latest version of the instructions can be found online at www germanpool com 1 2 Safety instructions Do not use the appliance until it has been correct...

Страница 3: ...on the mains side of the connecting box for appliances with a fixed connection The wall bracket must be secured with the supplied screws and dowels The appliance must be secured to the wall bracket Th...

Страница 4: ...r rating 2 86 kW Nominal current 13 A Hot water flow rate at t 25 K 2 2 0 L min Switching on at 1 2 L min Minimum required cable size 1 5 mm2 Approx weight filled with water 1 5 kg Product dimensions...

Страница 5: ...a 2 4 bar The appliance must not be subjected to pressure exceeding 1 MPa 10 bar For safe operation of this instantaneous water heater a non return valve is not required If nevertheless a non return v...

Страница 6: ...3 Water connection 1 Position the instantaneous electric water heater with the water connectors vertically upward or downward for direct connection to the tap 2 Secure the wall bracket to the wall wit...

Страница 7: ...ration card or online at www germanpool com 3 Installation As soon as the hot water tap is opened the instantaneous water heater switches on automatically Close the tap and the appliance switches off...

Страница 8: ...water emerges free of air bubbles 3 Switch the power supply back on again 4 5 Cleaning and maintenance Plastic surfaces and fittings should only be wiped with a damp cloth Do not use abrasive or chlo...

Страница 9: ...close other taps open angle valve further Water remains cold even though the appliance switches on Electric supply incorrect Check the electric supply No voltage Check fuses in the electrical install...

Страница 10: ...scrap 6 Disposal 6 1 Disassembly 1 Switch off the power supply to the instantaneous water heater 2 Close the shut off valve in the inlet pipe 3 Disconnect the electrical connection in the appliance ju...

Страница 11: ...2 1 5 1 5 kg x x 13 5 18 6 8 7 cm IES VDE IP25 No 812 2013 1 2 15 40 www germanpool com 0 6 MPa 0 6 MPa 1 1 1 1 2 2 2 1 2 2 2 3 3 3 1 3 1 1 3 1 2 3 2 3 3 3 4 3 5 4 4 1 4 1 1 4 1 2 4 2 4 3 4 4 4 5 5 6...

Страница 12: ...P 22 P 23 2 2 2 186 115 15 4 5 135 155 141 87 25 30 150 G 550 850 133 22 75 186 70 553 135 520 3 3 1 3 1 1 2 3 2 9 kW CSP 3...

Страница 13: ...P 24 P 25 3 2 German Pool DIN VDE 0100 EN 806 0 2 0 4MPa 2 4bar 1MPa 10bar 3 3 1 2 3 a b c d e 6 7 4 5 3 3 1 2 G 550 850 133 22 75 186 70 553 135 520 a a d b c e 3 2 9 kW CSP 3...

Страница 14: ...P 26 P 27 3 4 1 2 3 4 5 3 3 5 1 2 3 4 5 6 www germanpool com 3 220 V...

Страница 15: ...P 28 P 29 4 4 4 1 1 2 3 4 1 1 1 2 3 1 2 AAAA Ger t an Schutzleiter anschlie en Appliance must be earthed BBBB CCCC 3 4 1 2 1 2 4 2 40 30 25 20 10 0 0 0 1 0 2 0 l min K 3 0 4 0 5 0 2 9kW...

Страница 16: ...P 30 P 31 4 3 1 2 3 4 5 6 7 4 4 1 2 3 4 5 4 5...

Страница 17: ...P 32 P 33 35 5 6 1 1 2 3 4 5 15 6 6 1 10 2 15 3...

Страница 18: ...ill at its discretion repair or replace any defective part 5 This warranty will be void if there is any transfer of ownership from the original purchaser 1 2 3 4 5 Serial No Purchased From Invoice No...

Страница 19: ...Edificio Industrial Pou Fung 145 Rua de Francisco Xavier Pereira Macau Tel 853 2875 2699 Fax 853 2875 2661 Macau All rights reserved Copying reproducing or using the contents of this manual is not all...

Отзывы: