P.8
P.9
Angle valve outlet G ⅜”
Angle
v
alv
e appr
ox. 550
To
p e
dge
o
f basin appr
ox. 850
133
22
75
186
≧
70
Electrical connection with
mains power cable*
Cable
inle
t appr
ox. 553
13
5
Fast
ening appr
ox. 520
“Pressure-resistant (closed) installation with standard tap” (dimensions in mm)
* Please install according to local electrical regulations.
3.2 Installation instructions
The heater is installed as shown in the immediate vicinity of the outlet in a frost-free room. We guarantee
trouble-free operation only if German Pool fittings and accessories are used.
Note the following during installation:
• Installation must comply with DIN VDE 0100 and EN 806 and with the statutory regulations of the country
and the provisions of the local electricity and water supply company.
• Check technical data and the information on the rating plate under the cover.
• Ensure that all accessories are removed from the packing materials.
• Easy access to the appliance shall be guaranteed at all times. An external shut-off valve has to be installed.
• Thoroughly rinse the water pipes before connection.
• Optimum operation is ensured at a water flow pressure of 0.2 to 0.4 MPa (2–4 bar). The appliance must
not be subjected to pressure exceeding 1 MPa (10 bar).
• For safe operation of this instantaneous water heater, a non return valve is not required. If, nevertheless,
a non return valve has to be installed, it may only be placed in the hot water outlet line behind the instan-
taneous water heater.
• The minimum requirements for the required water resistance must be complied with. The required water
resistance of the can be obtained from your water supply company.
3.Installation
3.1.2 Pressure-resistant (closed) outlet installations
“Vented (open) installation with a special open-outlet tap” (dimensions in mm)
* Please install according to local electrical regulations.
Angle valve outlet G ⅜”
2.9 kW: CSP 3
Insert the special tap aerator:
Angle v
alv
e appr
ox. 550
Top edge of basin appr
ox. 850
133
22
75
186
≧
70
Electrical connection with
mains power cable*
Cable inle
t appr
ox. 553
13
5
Fast
ening appr
ox. 520
3.Installation
Installation, initial operation and maintenance of this appliance must only be conducted by an authorised
professional, who will then be responsible for adherence to applicable standards and installation regulations.
We assume no liability for any damages caused by failure to observe these instructions!
3.1 Typical installations
3.1.1 Vented (open) installation
2.9 kW: CSP 3
Insert the special tap aerator: