Model
DIS ELECTRONIC MPS®
Energy efficiency class
A *
)
Rated capacity / rated current
18 kW..27 kW (26 A..39 A)
Chosen capacity / current
18 kW (26 A)
21 kW (30 A)
24 kW (35 A)
27 kW (39 A)
Electrical connection
3~ / PE 380..415 V AC
3~ / PE 400 V AC
Min. required cable size
1)
4.0 mm
2
4.0 mm
2
6.0 mm
2
6.0 mm
2
Hot water (l/min)
max. at ∆t = 28 K
9.2
2)
10.7
2)
12.3
2)
13.8
2)
max. at ∆t = 38 K
6.8
7.9
9.0
2)
10.2
2)
Rated volume
0.4 l
Type
Pressure type 1.0 MPa (10 bar)
Heating system
Bare wire heating system IES ®
Required spec. water
resistance @ 15 °C
≥ 1100 Ωcm
Spec. electrical conductivity
≤ 90 mS/m
Inlet temperature
≤ 70 °C
Flow rate to switch on – max. flow rate
2.5 – 8.0 l/min
3)
Pressure loss
0.2 bar bei / at 2.5 l/min 1.3 bar bei / at 9.0 l/min
4)
Temperature choice
20 °C – 60 °C
Water connection
G ½"
Weight (when filled with water)
3.70 kg
VDE class of protection
I
Type of protection / safety
IP25
*) The declaration complies with the EU regulation No 812/2013
1) Maximum applicable cable size is 10 mm
2
2) Mixed water
3) Flow rate limited to achieve optimum temperature rise
4) Without flow regulator
3. Technical specifications
4. Dimensions
231
231
170
363
466
56
100
97
Dimensions in mm