Instructions for installer - CEX - 801045 - November 2018 v1.00 Art.no:
9120-25692
Installation site
• Appliance must only be installed in frost-free rooms. Never expose appliance to
frost.
• The Appliance must be wall mounted and has to be installed with water connectors
downward.
• The appliance complies with protection type IP24.
• To avoid thermal losses and dead legs, the distance between the instantane-
ous water heater and the furthest outlet should be kept as short as possible
(<6 meters). In addition all hot water pipe work should be insulated in accordance
with AS/NZS 3500.
• For maintenance work, a shut-off valve should be installed in the supplyline. The
appliance must be accessible for maintenance work.
• The specific resistance of the water must be at least 1000 Ωcm at 15 °C. The specific
resistance can be asked for with your water distribution company.
•
For 50 °C models:
The appliance delivers water not exceeding 50 °C in accordance
with AS3498.
•
For 60 ºC models:
The appliance may be able to be used with a thermostatic mix-
ing valve or where serving a fixture that does not require temperature limitation
such as a commercial kitchen sink or cleaners sink. Refer to AS/NZS 3500.4.
7. Installation
The following regulations must be observed:
• Installation must comply with all statutory regulations, as well as those of the
local electricity and water supply companies.
• The rating plate and technical specifications
• Only intact and appropriate tools must be used
• Installation must comply with all statutory regulations, AS/NZS 3000, AS/NZS
3500, as well as those of the local electricity and water supply companies
• These instructions must be read and fully understood before commencing the
installation. If in doubt, or in need of further guidance please ring Zip
on 1800 638 633