11.0
TECHNICAL DATA
11.1
PROCESS AND OPERATING DATA
11.1.1 BIRM CB1054 TO 1665
Model
CB
1054/EN
CB1248
/EN
CB1354
/EN
CB1465
/WC
Parameter
Units
Flow Rate
M3/hr
0.6
0.85
1
1.2
Backwash Flow
M3/hr
1.2
1.7
2.0
2.4
Regeneration
Time
Mins
20
20
20
20
Max. Operating
Temperature
Degrees
C
45
45
45
45
11.1.2 BIRM CB1665 TO CB 2160
Model
CB1665/
WC
CB1865
/WC
CB2160
/WC
Parameter
Units
Flow Rate
M3/hr
1.5
1.9
2.6
Backwash Flow
M3/hr
3.0
3.8
5.2
Regeneration
Time
Mins
20
20
20
Max. Operating
Temperature
Degrees
C
45
45
45