MAINTENANCE
The X117C and X117CLS are constructed of durable materials
which normally requiring no lubrication or periodic maintenance.
The two ‘O’ rings (2) (p/n 00951E) in the adapter (5) that seal
against the stainless steel actuating stem (1) will need replace-
ment if signs of leakage at the stem occur.
For replacement circuit board use p/n 3080206A. When installing a
new circuit board be sure that the small black and white plastic bear-
ing piece connecting the X117C main shaft to the circuit board
mounted potentiometer shaft remains in the transmitter housing. It
is not part of the replacement circuit board.
REFERENCE:
100 Series
1 1/4 & 1 1/2
2
2 1/2
3
4
6
8
10
12
14
16
600 Series
4
6
8
10
12
16
20 & 24
.60
.75
.88
1.00
1.13
1.50
1.88
2.00
2.87
3.00
3.25
Valve Size (inch)
“C” Dim. (inch)
CLA
-
VAL
Copyright Cla-Val 2011 Printed in USA Specifications subject to change without notice.
P.O. Box 1325
•
Newport Beach, CA 92659-0325
•
Phone: 949-722-4800
•
Fax: 949-548-5441
•
E-mail: [email protected]
•
Website cla-val.com
©
Span Trimmer
Potentiometer
Output Terminals
Null Trimmer
Potentiometer
Function Switch
Use “CW” Position
Right position:CW
Output increases
with clockwise
rotation of shaft
(viewed from front).
Left position:CCW
Output increases with
counter-clockwise
rotation of shaft
(viewed from front).
Figure 2. Rear View with Cover Removed
SPECIFICATIONS:
Voltage compliance range: 12.5 to 40 VDC
Maximum load resistance:
RL Max. =
V Supply - 12.5
20 mA
Current signal output: 4-20mA
Span: Adjustable from 15˚ to 90˚ of angular rotation
Null: 4 mA position may be set at any angular position
RL2 is current monioring instrumentation load
Typical Wiring Connections:
RL1
RL2
12.5 To
40 volts
SPAN
NULL
CCW CW
+
CW
CCW
N-X117C (R-3/2011)