  INSTRUCTION MANUAL 

RAPIFLOW® microflow type

FSM-H-A series

Please read this instruction manual carefully before using this product, 
particularly the section describing safety. 
Retain  this  instruction  manual  with  the  product  for  further  consultation 
whenever necessary. 

1.CAUTION 

The product can not be used as a business mater. Not conformed to 

the  Measurement  Law,  do  not  use  the  product  for  the  commercial 

purpose. Use the product as an industrial sensor. 

In  installation,  please  be  sure  to  hold  the  product’s  main  body  to 

prevent any impact to body and stress to the flying lead. 

Do not use the product with other than applicable working fluids, or the 

accuracy can not be guaranteed.   

Install a filter, an air dryer and an oil mist filter (micro alescer) onto the 

primary  side(upstream)  of  the  sensor  since  the  compressed  air  from 

the  compressor  contains  drain(water,  oil  oxide  and  foreign  material, 

etc.) Mesh(wire net) in a sensor is used to rectify the flow in the pipe. 

Always install a filter since this mesh is not a filter to remove  foreign 

materials, etc. 

Even  if twice  as much  as overflow as each  series measuring  range is 
applied to the sensor, it is no problem, however, if dynamic pressure is 
applied  near  to  the  maximum  working  pressure,  (when  the  pressure 
applied  to  the  primary  side  with  the  secondary  side  released.),  the 
sensor may fail. When feeding workpieces during leakage inspection, if 
dynamic  pressure  is  applied,  always  provide  a  by-pass  circuit  or  a 
needle valve to avoid dynamic pressure applying to the sensor.

2. Specifications 

Analog output type

Indicator type 

Descriptions 

FSM-H-A-

※1

ML-

※2

005 

0.25 to 5 

010 

0.5 to 10 

050 

2.5 to 50 

Flow rate range 

(m

/min)

 Note

※1

100 

5 to 100 

6A 

Stainless steel, Rc1/8   

Body material 

Port size 

※2

6G 

Stainless steel, G1/8 

Working fluid 

Note

Clean air (JIS B 8392-1.1.1 to5.6.2),   

compressed air(JIS B 8392-1.1.1 to1.6.2), and nitrogen gas 

Maximum working pressure

1.0MPa 

Minimum working pressure

-0.09MPa 

Withstanding pressure 

1.5MPa 

Ambient temperature/humidity

0 to 50

, 90%RH or less 

W

o

rk

in

co

nd

iti

on

Working fluid temperature

0 to 50

Linearity (display/analog output)

±

3%F.S. or less (0.1Mpa, 25

, flow rate range 5 to 100%F.S.) 

Pressure characteristics 

±

3%F.S. or less(-0.09 to 1.0 Mpa, 0.1Mpa criteria) 

Temperature characteristics

±0.2%

F.S.

/℃以下

(15 to 35

, 25

  criteria) 

A

cc

ur

ac

Repeatability (F.S.) 

±

0.5% F.S. or less 

Response time 

Note

50mS or less 

Display 

Power display (green

Analog output 

1 to 5V (connected load impedance 50k

Ω

and over) 

Power supply voltage 

DC12/24V(10.8 to 26.4V) 

Current consumption 

50mA or less 

Lead wire 

φ

3.7    0.2mm

3

×

3-conductor    1

Functions 

Analog output 

Installation attitude 

Both vertical and horizontal 

Strait piping section 

Not required 

Protective structure 

IP40 

Protective circuit

 Note

Power supply reverse protections 

EMC directive 

EN55011, EN61000-6-2,EN61000-4-2/3/4/6/8 

Mass 

140g 

Note1: Converted to volumetric flow at 20

  and 1 atmospheric pressure (101kPa) 

Note2: Consult with CKD for usage with a gas other than air and N2. 
Note3: The response time may change depended with piping condition. 
Note4:  The  protective  circuit  of  this  product  is  effective  for  the  special  incorrect  wiring  and  load  short 

circuits, but can not protect the product from all wrong connections. 

  Separate indicator 

Separate indicator 

Descriptions 

*1 

*2 

FSM-H-D 

NP

 - 

R0005

 ML 

005 

0

010 

0

10 

050 

0

50 

Flow rate range 

: mL/min 

*2

100 

0

100 

Display 

Flow rate display (7 segments 3 digits, orange),   

operation and switch output (orange) 

2 points 

(NPN open collector output, load current 50mA or less, 

voltage drop 2.4V) 

Switch output 

*1

2 points 

(PNP open collector output, load current 50mA or less, 

voltage drop 2.4V) 

Switch output 

response time 

Appx. 5ms 

Analog output 

Output 1 point 

(1 to 5 V voltage output, and connected load impedance 50 k

Ω

  and over)

Power supply voltage

DC12

24V 

10.8

26.4V

Current consumption

50mA or less (indicator only) 

Lead wire 

φ

3.7    0.2mm

2

×

5-conductor (1m) 

Functions 

Flow rate display, flow rate-peak hold, switch output, analog output 

Ambient 

temperature/humidity

0 to 50

, 85%RH or less (to be no dew condition) 

Protective structure 

IEC standards IP 40 

Mass 

Approximate 70g (including lead wire 1m) 

3. Wiring 

  Analog output type (FSM-H-A) 

Line color

Content 

Brown

Power supply DC12 to 

24V 

Blue 

0V(GND) 

Black 

Analog output 

(1 to 5V) 

Brown

Black 

Blue 

Load

M

ai

ci

rcu

it

  Separate indicator (FSM-H-D 

/

<Connection of display unit and sensor> 

11mm 

Electrical  connection  of  sensor  controller  is  made  with  terminal 
stand. 

Insert the wire while yellow jaw is pushed.

  Refer to the spec. below if other wires than those for the products 

are used.

Single-wire

0.14 to 0.5mm

Twisted-wire

0.14 to 0.5mm

AWG 

26 to 20 

<Separate indicator> 

  FSM-H-DN (separate indicator: NPN output

Black (out1) 

White (out2) 

Gray (analog output) 

Blue (power supply -) 

Brown (power ) 

MAX 50mA

MAX 50mA

Load2

Load1

M

ai

ci

rc

ui

+

-

DC12 to 

24V 

  FSM-H-DP(separate indicator: PNP output) 

Black (out1) 

White (out2) 

Gray (analog output) 

Blue (power supply-) 

Brown (power ) 

MAX50mA

MAX50mA

M

ai

ci

rc

ui

DC12 to 

24V 

Load1

Load2

+

-

(Precautions for wiring)

  Wiring 

For wiring, turn off the power supply. Discharge static electricity built 
in  body,  tool  and  equipment  before  and  during  work.  Use  a  wire 
elasticity as wire for robot connection in the movable part. 

  Wiring installation 

This  product  and  wiring  must  be  installed  as  far  away  as  possible 
from    noise  source  such  as  strong  electric  line,  etc.  Take  other 
countermeasures for a surge on the power supply line. 

  Power voltage 

Do not use the product put of power supply voltage range. If voltage 
more  than  usage  range  is  applied,  or  if  alternating  current 
power(AC100V) applied, causing damage or burn. 

  Short-circuiting 

Do not short-circuit a load, otherwise, or causing damage or burn. 

  Incorrect wiring 

Connect wires to the correct poles or terminals, otherwise, wires may 
be damaged or burned. 

  Separate indicator ;

By connecting display unit (FSM-A-D*) and flow sensor (analog output 
type: FSM-A), digital display and switch setting of flow rate is possible.   
The  controller  has  been  designed  exclusively  for  FSM.  Be  sure  to 
combine the controller and the sensor for the same flow rate. Never 
combine  the  other  flow  sensor,  FSM  for  other  flow  rate  or  pressure 
sensor. 

  FG connection 

Use  DC  safety  power  supply  thoroughly  insulated  from  the  AC 
primary  side  for  a  power  supply  for  the  metal  body  type,  while 
connecting  either  +  or  –  side  on  the  power  supply  to  F.G.  High 
potential  and  insulation  resistance  tests  between  the  inside  power 
circuit of metal body type and the metal body must not be done. 

4.Analog output voltage – flow rate characteristics

FSM-

-

-

0

F.S.

1

2

3

4

5

Analog 

output 

(V)

Flow rate
(

/min) 

(Precautions) 

Output accuracy is affected by 

self exoergics caused by 
energizing other than 
temperature characteristics. 
When using, stand-by time   

(5 minutes and over after 

energizing) must be provided. 

If out of flow rate range, the 

output will reach up to max 8V.

5.Piping

(Precautions for piping) 

 This  product  must  be  piped,  while  matching  the  flow  direction  and 

direction specified on the body. 

 When a valve is used in the primary side of the sensor, an oil-prohibited 

valve  must be used. The sensor may  malfunction or be destroyed by 
splash of grease and oil, etc.

 When piping in a resin tube, fix the piping as much as possible. When 

the piping moves during the flow control, abnormality of the flow output 
is caused as internal gas moves.

 When piping, apply a spanner on the metal section not to apply forces 

onto the resin section. 

  Never hold the plastic case for tightening.

  When piping, care must be taken that   

sealing tape and adhesive must not enter   
into the inside.

  During the piping work, be sure that   

any excessive screw-in torque and/or   
load torque will be applied to the piping port.

Set screw 

Tightening torque 

N・m

Rc1/8 

3 to 5 

G1/8 

3 to 5 

6.Installation

The  length  of 
stripping-wire 
Recommend 
length 

11mm

Analog type 

Separate indicator

S

ep

a

ra

te

 in

dic

a

to

r

Analog 

output 

type 

Blue (power supply-) 

Brown (power )

Black (signal conductor) 

How to connect analog output type 
  to separate indicator

V

S

G

This product is designed for air and compressed dry air and N

2

. Do 

not use it with combustible gases.   

Do not touch electric wiring connections (exposed live parts):  this 

will cause an electric shock. During wiring, keep the power off. Also, 
do not touch these live parts with wet hands.

Precaution 

!

Horizontal   

(through hole)

Vertical 

(female thread on the bottom)

Bracket installation 

(* bracket use) 

*  Bracket(separate  sales) 

is provided. 

(model no.: FSM-LB1)

<Separate indicator> 

  Bracket/kit (optional) are provided to install a separate indicator. 

Bracket model no.

PPD3-KL-D

single foot bracket (radical installation)

Bracket model no.

PPD3-KD-D

both sides foot brackets(parallel)

Bracket model no.

PPD3-KHS-D

panel mount bracket set with panel cover 

Bracket model no.

PPD3-KC

operation protective cover

7.External dimensions

<Analog output type> 

55 

15.5

1

7

27

9

.5

3

2

 

Rc1/8 or G1/8 

2-

φ

3.4 

2-M3 depth 5 

4

.6

<Separate indicator type> 

22

32

30

Sensor grand

2-

φ

2.7 depth 7

8. How to order

<Analog output type> 

FSM – H – A -    005    ML-    6A    -    K 

Symbol

Content 

Flow r ate rang e 

005 

0.25

5 m

/min 

010 

0.5

10 m

/min 

050 

2.5

50 m

/min 

100 

5

100 m

/min 

Port  size  

6A 

Rc1/8 (stainless steel) 

6G 

G1/8 (stainless steel) 

Option

Blank 

None 

Company Certification attached 

Traceability attestation attached. 

3  pieces;  traceability  attestation, 
company  certification  and  traceability 
system configuration are attached. 

<Separate indicator> 

FSM – H –D    N    -    050    ML 

Symbol

Content 

Ou tput type 

NPN output 

PNP output 

Flow r ate range 

005 

0.25 to 5 mL/min 

010 

0.5 to 10 mL/min 

050 

2.5 to 50 mL/min 

100 

5 to 100 mL/min 

<Bracket for separate indicator> 

PPD3 -    KL - D 

Symbol

Content 

Brack et  k it 

KL-D 

Single foot bracket (radial) 

KD-D 

Both sides foot brackets (parallel)

KHS-D 

Panel mount bracket set with cover

KC 

Operation protective cover 

Mounting hole 

machining dimensions

2-nominal 3

P tight 

2-M3

18

4-M3

18

50

□33.5±0.3

Protective cover 

Protective cover holder 

FSM-H-A-        ML-6A/6G 

FSM-H-D

050

Mounting hole 

machining dimensions

2-nominal 3

P tight 

Mounting panel cutout

2-250, Ouji

2-Chome

Komaki

Aichi

485-8551, Japan 

http://www.ckd.co.jp/ 

2006.12.13