FCM
Series
Communication specifications
Process data OUT
[Reference]
Accumulated flow
calculation example
PD
PD0
PD1
Bit
31
30
29
28
27
26
25
24
23
22
21
20
19
18
17
16
MSB
LSB
Data name
Set flow rate *1
Data range
2 byte (depends on model. Refer to P14 Table 1 ProcessData output values)
Format
UInteger16
Bit
79
78
77
76
75
74
73
72
71
70
69
68
67
66
65
64
0
0
0
0
0
0
0
0
0
0
0
0
1
1
1
1
hex
000F
Data name
Integrating flow unit upper byte
Bit
63
62
61
60
59
58
57
56
55
54
53
52
51
50
49
48
0
1
0
0
0
0
1
0
0
0
1
1
1
1
1
1
hex
423F
Data name
Integrating flow unit lower byte
PD
PD2
PD3
Bit
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
Data name
Vacant
Preset *2
Vacant
Accumulation
Vacant
Reset
Start/
stop
*3
3
2
1
Reset Stop
Data range
0 to 7
True/False
True/False
Format
UInteger3
Boolean
Boolean
*1: Set to "9999" for "valve fully open".
*2: Preset memory number and bit combination
Process Data OUT Preset
Preset memory
number
Bit 3
Bit 2
Bit 1
0
0
0
P1
0
0
1
P2
0
1
0
P3
0
1
1
P4
1
0
0
P5
1
0
1
P6
1
1
0
P7
1
1
1
P8
Perform preset memory content settings using key operations on the device or using IO-Link communication parameters.
*3: Set this bit to 1 (True) if using IO-Link communication control. Control will not execute if set to 0 (False).
Note the following wh
en using flow contro
l/forced OFF via device key input.
Note: The "start/stop" bit of Process Data OUT has the same role as "Flow control/Forced OFF" status switched by key operation.
However, when the "start/stop" bit is "1 (Start)", if th
e flow control is fo
rcibly turned OFF via key input from the device, the "start/stop" bit of Process
Data IN will be "0 (Stop)" and the product will be in the forced OFF, but the "start/stop" bit of Process Data OUT will remain as "1 (Start)". Therefore,
always check the "start/stop" status of the device using the "start/stop" bit of Process Data IN.
Also, when switching the "
start (flow control)
" state from the master in this state, set it to "0 (stop)" and then set it to "1 (start)" again.
Refer to the SM-A19060 instruction manual for usage methods.
000F 423F (hex)
⇒
999999 (dec)
For FCM-0005*-*C, Table 1 on P14 shows the integrating
flow as 99999.9 L.
16