CKD EVD Series Скачать руководство пользователя страница 4

Intro 2

Safety Precautions

Always read before starting use

1

2

3

4

5

The safety cautions are ranked as "DANGER", "WARNING" and "CAUTION" in this section.

DANGER:

WARNING:

CAUTION:

WARNING

When designing and manufacturing a device using CKD products, the manufacturer is 
obligated to check that device safety mechanical mechanism, pneumatic control circuit, or 
water control circuit and the system operated by electrical control that controls the devices is 
secured.
It is important to select, use, handle, and maintain the product appropriately to ensure that the 
CKD product is used safely.
Observe warnings and precautions to ensure device safety.
Check that device safety is ensured, and manufacture a safe device.

This product is designed and manufactured as a general industrial machine part.
It must be handled by an operator having sufficient knowledge and experience in handling.

Use this product in accordance of specifications.

Observe corporate standards and regulations, etc., related to the safety of 
device design and control, etc.

Observe warnings and cautions on the pages below to prevent accidents.

Do not handle, pipe, or remove devices before confirming safety.

1

2

1

2

3

4

Contact CKD when using the product outside the unique specifications range, when using it outdoors, and when 
using it under the conditions and environment below. Do not attempt to modify or additionally machine the product.

Use for special applications requiring safety including nuclear energy, railroad, aviation, ship, vehicle, 
medical equipment, equipment, or applications coming into contact with beverage or food, amusement 
equipment, emergency shutoff circuits, press machine, brake circuits, or for safeguard.
Use for applications where life or assets could be adversely affected, and special safety measures are 
required.

Inspect and service the machine and devices after confirming safety of the entire system related to this 
product.
Note that there may be hot or charged sections even after operation is stopped.
When inspecting or servicing the device, turn off the energy source (air supply or water supply), and turn off 
power to the facility. Discharge any compressed air from the system, and pay enough attention to possible 
water leakage and leakage of electricity.
When starting or restarting a machine or device that incorporates pneumatic components, make sure that 
the system safety, such as pop-out prevention measures, is secured.

ISO 4414, JIS B 8370 (pneumatic system rules), JIS B 8368 (pneumatic cylinder), JPAS 005 (principles for 
pneumatic cylinder use and selection), High Pressure Gas Maintenance Laws Occupational Safety and 
Sanitation Laws, and other safety regulations, corporate standards, and regulations.

When a dangerous situation may occur if handling is mistaken leading to fatal 
or serious injuries, or when there is a high degree of emergency to a warning.

(DANGER)

(WARNING)

(CAUTION)

When a dangerous situation may occur if handling is mistaken leading to fatal 
or serious injuries.

When a dangerous situation may occur if handling is mistaken leading to 
minor injuries or physical damage.

Note that some items described as "CAUTION" may lead to serious results depending on the 
situation.
In any case, important information that must be observed is explained.

Содержание EVD Series

Страница 1: ...1 Digitalelectropneumaticregulator EVD series CC 764A Compact high function digital control New product...

Страница 2: ...ge methods Direct memory function External input signals are not required Secondary pressure is adjusted as desired with operation keys Switch output function Switch outputs built in overcurrent prote...

Страница 3: ...trol Air turbine speed control Fixing of lead frames etc Assembly of chips EVD Cylinder Solenoid valve Grindstone Motor Controller EVD Air turbine EVD Tip EVD Lead frame EVD EVD Tank Magnetic tape Air...

Страница 4: ...uipment or applications coming into contact with beverage or food amusement equipment emergency shutoff circuits press machine brake circuits or for safeguard Use for applications where life or assets...

Страница 5: ...d valve relay etc and remove noise where generated Keep wiring to the device separate from strong magnetic fields Connect wiring to the device with a shield wire Ground the shield wire on the power su...

Страница 6: ...e Do not use a load exceeding the output rating Failure to observe this may result in output damage or fire Installation Adjustment Installation WARNING Connector pin and cables conductors color must...

Страница 7: ...agent on pipe connections with a brush and check for air leaks Lock the D sub connector so that it does not move Fix the fixed bed with a tool etc when releasing the screw lock CAUTION Piping The opt...

Страница 8: ...m that it is operating correctly This case is made of resin Do not use solvent alco hol or detergent when cleaning because resin could be damaged Wipe off dirt with a rag dampened in a diluted neutral...

Страница 9: ...kPa 0 5 F S or less 0 3 F S or less 0 2 F S or less 0 3 F S or less 0 15 F S or less 0 07 F S or less 400 min 0 2sec or less loadless 98 m s2 or less 5 to 50 5 to 50 Rc1 4 Free 250g Power supply rever...

Страница 10: ...nitrile rubber Aluminum alloy SUJ Special nitrile rubber and stainless steel Silicon rubber Brass and electroless nickeling Fluoro rubber Blank C1 C3 P1 P3 None Analog 9 conductor cable 1 m Analog 9 c...

Страница 11: ...age 9 for cable option dimensions 1 6 3 5 3 5 44 36 30 56 64 4 4 4 4 27 36 27 1 6 44 22 8 3 5 4 full R 7 2 32 22 42 42 4 full R 5 17 5 4 4 30 5 51 36 27 10 48 6 OUT IN 42 100 21 107 18 27 36 5 3 EXH p...

Страница 12: ...ure Input signal kPa 0 0 200 400 600 100 200 300 400 600 500 Control pressure Flow rate min Working pressure 0 7MPa Working pressure 0 7MPa kPa 0 0 100 200 300 400 100 200 300 400 600 500 Control pres...

Страница 13: ...ting minimum width 1kPa 0 5 F S or less 0 3 F S or less 0 2 F S or less 0 3 F S or less 0 15 F S or less 0 07 F S or less 1500 min 0 2sec or less loadless 98m s2 or less 5 to 50 5 to 50 Rc1 4 Rc3 8 Fr...

Страница 14: ...ess steel Special brass and nitrile rubber Special brass and nitrile rubber Brass Nitrile rubber Steel sheet 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 Blank C1 C3 P1 P3 None Analog 9 coductor cable 1...

Страница 15: ...tion dimensions Rc3 8 EXH port 6 6 30 50 24 38 32 24 38 87 71 53 2 12 1 6 8 4 5 32 36 5 61 5 24 38 24 38 7 26 36 50 7 22 2 3 8 4 5 50 4 full R 52 4 133 OUT 24 38 50 IN 25 7 140 78 25 8 2 M4 depth12 D...

Страница 16: ...200 300 400 600 500 Control pressure kPa 0 0 1000 2000 3000 4000 100 200 300 400 600 500 Control pressure kPa 0 0 1000 2000 3000 4000 100 200 300 400 600 500 Control pressure kPa Flow rate min Flow ra...

Страница 17: ...n 0 to 10 VDC Vacant Vacant Monitor output Output short circuit protection circuit 1 to 5 VDC Switch output NPN or PNP output Error output NPN or PNP output Power supply 0V Type of input Isolator colo...

Страница 18: ...M E M O M E M O 10...

Страница 19: ...15 power supply max 50mA Signal generator Load Load Output short circuit protection circuit Main circuit Signal generator Pin 5 power supply Pin 13 monitor output Pin 11 analog input Pin 14 error out...

Страница 20: ...8 Pin 8 bit 7 Pin 7 bit 6 Pin 6 bit 5 Pin 4 bit 4 Pin 3 bit 3 Pin 2 bit 2 Pin 1 LSB bit 1 Pin 13 switch output Pin 14 error output Pin 15 power supply max 50mA max 50mA Load Load Main circuit Pin 5 p...

Страница 21: ...and setting are confirmed When Mode 1 valid is selected F4 0 tolerable range setting L tolerable range setting H is alternately displayed When Mode 2 valid is selected F4 1 lower limit setting value...

Страница 22: ...pan adjustment and the setting are confirmed Note This is invalid if preset or direct memory input is selected for F1 mode F4 switch output function Screen F4 display details Switch output validity an...

Страница 23: ...n F1 After setting exits setting mode and returns to screen F1 After setting exits setting mode and returns to screen F1 To select analog input Default Changing parallel input signal selection Input t...

Страница 24: ...After setting exits setting mode and returns to screen F2 To use with adjusted zero span 2 seconds and over Input the set value key Moves digit key Counts up value Input the set value key Moves digit...

Страница 25: ...scriptions Setting specifications Set the target pressure Range 000 to 500 Minimum setting 1 kPa Range 000 to 500 Minimum setting 1 kPa Range 00 to 50 Minimum setting 1 Range 00 to 50 Minimum setting...

Страница 26: ...e and turn power on again Check the regulator s input signal set the input signal within the rated range and turn power on again Check primary pressure supply pressure within the rating and turn power...

Страница 27: ...0 3 5541 1468 FAX 60 0 3 5541 1533 JOHOR BAHRU OFFICE 116 118 Jalan Rosmerah 2 17 Taman Johor Jaya 81100 Johor Bahru Malaysia PHONE 60 0 7 352 9129 FAX 60 0 7 352 9144 MELAKA OFFICE No B 10 Ground Fl...