g5.Voltage Input(3-Line System)Connection Diagram 

2)

 Current Input Type (2-Line System) Connection   

Use the 6mm external diameter, 2-core shield cable 0.5-1 5mm

2

 for a device controlled with input 

signal of 4mA -20mA current. To avoid connected to a malfunction caused by noise, the shield cable 
must be connected to Ground at the operation side as same as at the Voltage Input Type. 

As Figure4 indicates, connect to the respective terminals as indicated in Fig7. 

 

Fig6.2-line Input Cable 

WIRING 

 

Discontinue

Содержание ER300

Страница 1: ...C T R O P N E U MA T I C R E G U L A T OR E R 3 0 0 Please read this instruction manual carefully before using this product particularly the section describing safety Retain this instruction manual with the product for further consultation whenever necessary Discontinue ...

Страница 2: ...ments and how to use it This product incorporates many functions and mechanisms to ensure safety However improper operation could result in an accident To pre vent such accidents read this operation manual carefully for proper operation Observe the cautions on handling described in this manual as well as the following instructions Failure to pay attention to DANGER notices may cause a situation th...

Страница 3: ...as deteriorated product characteristics result 2 The products response capability will be affected by the working pressure and load volume When a stable response is required regulate the working pressure 3 When the product is used with the secondary side being opened to the atmosphere as in the case of air blowing air pressure may vary depending on conditions of piping and air blowing In such a ca...

Страница 4: ...power line from the ER300 signal cable Connect the ER300 signal cable with the shield cable 1 Install a line filter in the ER300 source power supply for example when using the DC power supply pack install in the DC power supply pack AC side Warning When the above precautions are not provided normal pressure control cannot be guaranteed Important Connect the shield to the GND For the connection bet...

Страница 5: ...s PARECT Electronic Regulator INSTRUCTION MANUAL No SM 276677 A 1 PRODUCTS 1 1Specifications 5 1 2Dimensions 6 2 WIRING 2 1Terminal Box 7 2 2Connection 7 3 PRODUCT OPERATION 3 1Adjustment 1 0 4 HOW TO ORDER 11 DEC 01 1999 Discontinue ...

Страница 6: ...ty 0 5 F S or less 1 Maximum flow rate 2 700L min ANR 2000L min ANR 2500L min ANR Step response 3 2sec or less no load Air comsumption rale ANR 3L min or less Withstanding vibration 39m s2 30Hz Working temperature range 5 50 Monitor output 4 1 0 3V 3 5 0 6V 1 0 3V 3 5 0 6V 1 0 3V 3 0 0 6V Dimensions See to 1 2 Dimensions Port size Rc1 4 3 8 Mass 0 9kg 1 This specification is when the conotrol pres...

Страница 7: ... SM 276677 A 6 1 2 Dimensions Port size D Rc3 8 Rc1 4 Fig2 Dimensions PRODUCTS 1 Discontinue ...

Страница 8: ...pe 3 line system Connection Use the 6mm external diameter 3 core shield cable 0 5 1 5mm2 for a device controlled with input signal of 0VDC 10VDC or 0VDC 5VDC voltage To avoid a malfunction caused by noise the shield cable must be connected to Ground Common at the operation side Fig4 When used in an poor environment power supply noise must be eliminated with the line filter and the serge killer As ...

Страница 9: ...d cable 0 5 1 5mm2 for a device controlled with input signal of 4mA 20mA current To avoid connected to a malfunction caused by noise the shield cable must be connected to Ground at the operation side as same as at the Voltage Input Type As Figure4 indicates connect to the respective terminals as indicated in Fig7 Fig6 2 line Input Cable WIRING 2 Discontinue ...

Страница 10: ...an be used only for the Voltage Input Type 3 Line System device It cannot be used for the Current lnput Type 2 Line System Connect to the terminals as indicated in Figure5 with the 6mm external diameter 0 5 1 5mm2 2 core shield cable as indicated in Fig8 Fig7 Current Input 2 line System Connection Diagram Fig8 Monitor Output Cable WIRING 2 Discontinue ...

Страница 11: ...eases the pressure and counterclockwise turn of the trimmer decreases the pressure Procedure 3 Span adjustment First turn on the power and apply the rated voltage or current 10 VDC 5 VDC or 20mADC depending on the model Then turn the span adjustment trimmer either clockwise or counterclockwise to obtain the rated output Clockwise turn of the trimmer increases the pressure and counterclockwise turn...

Страница 12: ...Symbol Optional blacket No symbol Nothing B Blacket attached Symbol Port size 08 Rc1 4 10 Rc3 8 Symbol Input signal 0 0VDC 10VDC 1 0VDC 5VDC 2 4mADC 20mADC Symbol Pressure control range 1 0kPa 98kPa 5 0MPa 0 49MPa 8 0MPa 0 78MPa MODEL 4 Discontinue ...

Отзывы: