CN56X0B-X Reader User Manual
43
/
47
1) Drill four holes on the Installation location at mounting plate;
2) Plug rubber stopper;
3) Install mounting plate on the Installation location;
4) Twist four screws fixed mounting plate;
5) Attach the reader to mounting plate.
13 Connection Diagram
13.1 RS232 connection diagram
J3
:
9-24V
DC Power input, DC(9~24V)
GND Groud
TX
Connect to RS232 TX of PC
RX Connect to RS232 RX of PC
WD1 Data1 signal (connect an external wiegand reader Data1)
WD0 Data0 signal (connect an external wiegand reader Data0)