CN56X0B-X Reader User Manual
34
/
47
9.9 Restore factory defaults via keypad
If you don’t want using web page to restore the factory defaults, or you don’t know the IP address, so
can’t access web pages of the machine, you can use the another way to recover it.
1) Make sure the machine in power off status
2) Keep the “#” key in down status, and then power the machine on.
If the restore factory defaults successfully, the green led and the red led which on the front board
of the machine will in flicking status alternately.
3) Reset the machine via power off and power on.
If the operation failed, please repeat Step1 to Step3.
Note:
Restore factory set the IP address for 192.168.1.120
10 TCP/IP communication test and failed solution
In network structure, the router is essential. After our product add in the network environment.
You need to test the communication from your host PC to machine. The test procedure as follows:
10.1 TCP/IP communication test
1) Make sure the connection between host PC and the machine for TCP/IP communication is
created.
2) Power on the machine
3) Enter in Dos system window. ( We presume the OS of your host PC come from Microsoft
series.)