background image

 

 

Introduction

 

The QolorFLEX 5x2.5A 900MHz/2.4GHz Multiverse Dimmer requires standard DC power from 
5-30VDC. The input voltage must be the same as the load connected to the output ports 
requires. 
 
C

onnect your power supply’s DC “+” and “-” to the two DC input terminals on the 5942 labelled 

“PWR” “+” and “-”.   
 
C

onnect the “+” lead(s) of the load device(s) to the “+” “OUTPUT” terminal, and connect the “-” 

leads of the load device(s) to “A”, “B”, “C”, “D”, and “E” “OUTPUT” terminals.   

 
NOTE:

 Terminal connectors may be detached from the unit for ease of wiring. Check wiring 

connections carefully before reinserting connectors, and reinsert connectors carefully into their 
intended positions. 
 
U

se the “A”, “B”, “C”, “D”, and “E” bump buttons to check your connections prior to applying 

DMX control. 
To set DMX Termination Switch: 

□ 

“ON FOR ALL WIRELESS USE”  

□ 

“OFF”:  When used as a wired dimmer and DMX is passing through to another 

DMX device 

□ 

“ON WIRED”:  When used as a wired dimmer and it is the last device in a DMX 

chain 

 

Important

 

setup information! 

 
U

nit ships defaulted to “wired” mode, and RDM configuration begins in that mode.    

The status light shows green for wired mode, blue for wireless mode, and red for fault detected. 
 
Revert to wired mode and reset 

all

 

factory defaults by holding down the “A” and “E” bump 

buttons together for five seconds until the “STATUS” and “SIGNAL QUALITY” lights flash in 
unison.  
 
Revert to wired mode 

without changing any other settings

 

by holding down the “B” and “D” 

bump buttons together for five seconds until the “STATUS” and “SIGNAL QUALITY” lights flash 
in unison. 
 

Factory Default Settings 

 
DMX tab 
- RDM Traffic Enabled 
- DMX Port Label: Label 
- Universe 1 
- DMX Address 1 
- DMX Personality   8-Bit (5ch) 
 
Dimmer tab 
- Bump Buttons Enabled 
- Apply to All: No 
- Device Label: Default Dim 1 Label 
- Curve Logarithmic (LED) 

Содержание QolorFLEX

Страница 1: ...wired Blue for wireless Solid for DMX present Blinking when no DMX present Blinking Red for fault codes Signal Quality Lights Made in the USA Output Indicator Lights Bump Buttons Termination Switch Multiverse Technology Inside Error Codes Number of blinks 1 Short circuit 2 Output overcurrent 4A on any output 3 Input overcurrent 12 5A on total device 4 Over temperature on any output 5 Under voltage...

Страница 2: ...LL WIRELESS USE OFF When used as a wired dimmer and DMX is passing through to another DMX device ON WIRED When used as a wired dimmer and it is the last device in a DMX chain Important setup information Unit ships defaulted to wired mode and RDM configuration begins in that mode The status light shows green for wired mode blue for wireless mode and red for fault detected Revert to wired mode and r...

Страница 3: ...re making any setting changes Set Device Label user selectable name Select Dimmer Curve changes the slope of the dimmer curve Select Output Response Time lengthens the dimmer response time to achieve smoother dimming Modulation Frequency sets the dimming PWM to prevent interference or flickering with film and video camera shutters Set Control Offset At very very low levels in slow fades the LED em...

Страница 4: ...hoices are Low Medium High Choose a SHoW Key if desired NOTE Universe SHoW ID and SHoW Key must match between Transmitter and 5942 Now change the DMX Input Mode from the default Wired to Wireless At this point you will lose control over the 5942 since it is now a wireless device and will receive an error message the STATUS light will turn blue and will be blinking if there is no DMX being received...

Отзывы: