The QolorFLEX 5x2.5A 900MHz/2.4GHz Multiverse Dimmer requires standard DC power from
5-30VDC. The input voltage must be the same as the load connected to the output ports
requires.
C
onnect your power supply’s DC “+” and “-” to the two DC input terminals on the 5942 labelled
“PWR” “+” and “-”.
C
onnect the “+” lead(s) of the load device(s) to the “+” “OUTPUT” terminal, and connect the “-”
leads of the load device(s) to “A”, “B”, “C”, “D”, and “E” “OUTPUT” terminals.
NOTE:
Terminal connectors may be detached from the unit for ease of wiring. Check wiring
connections carefully before reinserting connectors, and reinsert connectors carefully into their
intended positions.
U
se the “A”, “B”, “C”, “D”, and “E” bump buttons to check your connections prior to applying
DMX control.
To set DMX Termination Switch:
□
“ON FOR ALL WIRELESS USE”
□
“OFF”: When used as a wired dimmer and DMX is passing through to another
DMX device
□
“ON WIRED”: When used as a wired dimmer and it is the last device in a DMX
chain
Important
setup information!
U
nit ships defaulted to “wired” mode, and RDM configuration begins in that mode.
The status light shows green for wired mode, blue for wireless mode, and red for fault detected.
Revert to wired mode and reset
all
factory defaults by holding down the “A” and “E” bump
buttons together for five seconds until the “STATUS” and “SIGNAL QUALITY” lights flash in
unison.
Revert to wired mode
without changing any other settings
by holding down the “B” and “D”
bump buttons together for five seconds until the “STATUS” and “SIGNAL QUALITY” lights flash
in unison.
Factory Default Settings
DMX tab
- RDM Traffic Enabled
- DMX Port Label: Label
- Universe 1
- DMX Address 1
- DMX Personality 8-Bit (5ch)
Dimmer tab
- Bump Buttons Enabled
- Apply to All: No
- Device Label: Default Dim 1 Label
- Curve Logarithmic (LED)