City Theatrical QolorFLEX 5750 Скачать руководство пользователя страница 6

6

1. DMX Present LED:  Indicates DMX512 Data is being received, blinks if no data is

present.

2. Dimmer Pilot Light LEDs:  Fade up and down with the dimmer to permit easy monitoring

and testing

3. Status LED:  Indicates the following error/fault conditions:

Condition

Blink

 

Pattern

 

Blinks

 

followed

 

by

 

1sec

 

pause

 

UNDER

 

VOLTAGE

 

.

   

.

  

.

 

1

 

INVALID

 

DMX

 

ADDRESS

..

  

..

  

..

 

2

 

OUTPUT

 

OVER

 

CURRENT

….

  

….

  

….

 

4

 

INPUT

 

OVER

 

CURRENT

…..

 

…..

 

…..

 

5

 

OVER

 

TEMP

……

  

……

  

……

 

6

 

OVER

 

VOLTAGE

…….

  

…….

  

…….

 

7

 

OUTPUT

 

SHORT

 

CIRCUIT

……..

 

……..

 

……..

 

8

 

4.

Bump Buttons:  A bump button is provided for each channel output

.

5.

Curve Selection DIP Switch (

eight

 position): Select the dimming curve for each of the

individual dimmer outputs in the unit

.

  (See page 8)

6.

MOD (Mode) Selection DIP Switch (

two 

position):  Select the PWM modulation

frequency

 

for dimmer channels set to the LED Curve. (See page 8)

7.

10V Dip Switch (

one

 position): Set this to OFF if this function is not in use or if your

device

 

provides the voltage for 0-10V control. Otherwise set this to ON.

8.

R DIP Switch (

one 

position): Setting this 

r

eset switch to ON resets the Dimmer and

holds

 

in reset until set to OFF.

9.

T Dip Switch (

one 

position):  Setting this termination switch to ON connects end-of-line

DMX termination.

QolorFLEX

®

 4x10A

 Dimmer RDM Parameter IDs 

The 

QolorFLEX 4x10A

 Dimmer supports all the mandatory RDM Parameter IDs (PIDs) 

plus the following PIDs: 

PROXIED_DEVICE_COUNT 
PROXIED_DEVICES_ENHANCED 
SUPPORTED_PARAMETERS 
PARAMETER_DESCRIPTION 
DEVICE_MODEL_DESCRIPTION 
MANUFACTURER_LABEL 
DEVICE_LABEL 
FACTORY_D

 

EFAULTS 

SOFTWARE_VERSION_LABEL 
DMX_BLOCK_ADDRESS 
SENSOR_DEFINITION 
SENSOR_VALUE 
RECORD_SENSORS 
OUTPUT_RESPONSE_TIME 
OUTPUT_RESPONSE_TIME_DESCRIPTION 

Содержание QolorFLEX 5750

Страница 1: ...QolorFLEX 4x10A Dimmer 5750 User s Manual Rev 1 03 2019 City Theatrical Inc ...

Страница 2: ...e 5 4x10A Dimmer RDM Parameter IDs 6 DMX addressing 7 Selecting Dimmer Curves 8 Smoothing Dimmer Response Time 9 Using 4x10A Dimmer with CTI Flicker Candles 9 Appendix A Using QolorFLEX series Dimmers with LED Tape 10 How much Tape can I use with one 4x10A Dimmer 10 Connecting Single Color Tape 10 Connecting Three Color RGB or Four Color RGBW RGBA LED Tape 11 4x10A Dimmer Specifications 11 DMX Con...

Страница 3: ...e with all pertinent local regional and national safety codes and regulations The QolorFLEX 4x10A Dimmer is intended for indoor use The unit enclosure is rated NEMA 1 IP20 Rated operating voltage 100 240 VAC 10A max Maximum operating temperature 0 C 40 C Introduction Thank you for using City Theatrical s QolorFLEX 4x10A Dimmer The QolorFLEX 4x10A Dimmer represents new benchmarks for control featur...

Страница 4: ...ts per channel 10 Amps per channel FCC and CE Certified Fan Cooled Attached power cord Mounting Every effort has been made to anticipate your questions in this manual but if you have any questions that are not answered here or you want to discuss a special application please feel free to contact us directly at City Theatrical QolorFLEX 4x10A Front View ...

Страница 5: ...12 A Input Output The QolorFLEX 4x10A Dimmer supports five pin XLR DMX512 A input as well as RJ 45 input which is a lower cost alternative to DMX cable Once connected the DMX start address can be changed using the three rotary switches on the front panel of the unit A single position DIP switch is provided as a DMX termination switch if the unit is at the end of the DMX line The Termination switch...

Страница 6: ...dulation frequency for dimmer channels set to the LED Curve See page 8 7 10V Dip Switch one position Set this to OFF if this function is not in use or if your device provides the voltage for 0 10V control Otherwise set this to ON 8 R DIP Switch one position Setting this reset switch to ON resets the Dimmer and holds in reset until set to OFF 9 T Dip Switch one position Setting this termination swi...

Страница 7: ...switches are labeled as 100 s 10 s and 1 s To set the starting address simply twist the rotary switches to match the desired starting address and the remaining three slots are addressed contiguously The highest starting address that can be set by the rotary switches is limited to 509 in the 4x10A Dimmer DMX addressing may also be set using RDM When RDM is used the individual dimmer channels may be...

Страница 8: ...t mode and is intended for controlling LEDs but may be used for other specialized loads The LED Curve Modes have been optimized for flicker free performance in TV and Film applications All settings have been camera tested with motion picture film and digital cinema cameras The settings are different to allow compensation for variations in shutter speed and shutter angle A camera test is recommende...

Страница 9: ...six different smoothing settings can be selected using RDM The smoothing setting determines how quickly the dimmer responds to changes in DMX level With the fastest smoothing setting 5ms the dimmer and connected LED loads will respond immediately to any level change As longer smoothing settings are selected the dimmer and connected LED loads will ramp more smoothly between DMX levels simulating th...

Страница 10: ...optimize load wiring designs by minimizing run length assuring termination quality and assuring adequately sized wire is used Appendix A Using QolorFLEX Dimmers with LED Tape The CTI 5700 QolorFLEX Dimmers have been optimized for use with 12V LED tape The 4x10A Dimmer can be used with single color two color variable white three color RGB or four color RGBW RGBA tape How much Tape can I use with on...

Страница 11: ...to change the PWM frequency use RDM or the MOD DIP switch to select the frequency desired QolorFLEX 4x10A Dimmer Specifications DMX Control Features The QolorFLEX 4x10A Dimmer Includes Rotary switches for DMX addressing 0 10V input control DMX 5 pin XLR terminals for input Pass Thru Ethernet Terminals for DMX In Pass Thru o Note a total of one input and one output may be used per 4x10A Termination...

Страница 12: ...dual bump buttons PWM resolution 16 bit Dimming Curves o Linear 60Hz o ISL 60Hz o Non Dim LED Features o Six variable LED smoothing rates o Five TV Film Modes Compliance ETL Listed to UL508 A CE Certified o Emissions Immunity o Electrical Safety o WEEE o Sustainability o RoHS Compliant CTI Part s 5750 QolorFLEX 4x10A Dimmer Power 100 240 VAC 10A Max Power Input Weight 6 7 lbs 3 kg Dimensions 12 25...