Page 8 of 12
•
Auto Off Time
Auto Off allows the user to set a time to turn off the Multiverse Studio if no radio
signal is detected from a Multiverse Transmitter while battery power is being used.
Settings are 30 minutes to 10 hours, or off. Default is 8h 00m. Whenever a radio
signal is received, or when the user presses a button, the time counter begins
again.
•
Backlight Time
The Backlight Timeout setting determines how long the LCD backlight will remain
on after the last button press. The timeout can be set to off (backlight will never
timeout) or any interval from 10 seconds to 30 minutes. Default is off. After a
screen timeout, pushing any button will wake up the screen without changing the
screen selection.
•
Backlight Level
Controls Backlight brightness. Range is 25%-100%. Default is 70%, which allows
20 hour battery life. 100% brightness allows 16 hours battery life.
•
Lock Screen
The user interface screen can be locked to prevent accidental or malicious
changes, while leaving the SHoW ID/Universe display visible. To unlock the
screen, use a long press on the menu button.
•
Factory Defaults
Resets all settings to factory defaults.
•
Battery Info
Provides information on battery status
•
Multiverse Info
Provides information on Multiverse Studio’s radio
•
Firmware Info
Lists all firmware versions loaded
•
Update Firmware
Puts Multiverse Studio into firmware update mode
RDM Settings
The Multiverse Studio Receiver can be configured remotely with a compatible RDM controller,
such as DMXcat®. All of the settings available through the menu can be set via RDM. Aside
from settings, you can also view the Device Model, Manufacturer, Firmware Versions, RDM
UID, RF Signal Quality, RF Signal Strength, and Battery Charge %. You can also give each
device a unique RDM Device Label to help with identification for configuration and
troubleshooting.
Updating Firmware
Firmware updates and instructions for performing them are available on the product pages of