© Citrin 11234 CS 2.5.monen.ind
d
Page 42
CitrinSolar CS 2.5
CitrinSolar Energie- u. Umwelttechnik GmbH
•
Böhmerwaldstr. 32
•
D-85368 Moosburg
•
Tel.:+49 (0) 8761/33400
•
Fax: +49 (0) 8761/334040
Display of collector temperatures
TCOL(1, 2)
Collector temperature
Display range: -40 ... +260 °C
Display of store temperatures
Displays the current store temperature.
• TSTB : Store temperature base
• TSTT : Store temperature top
in 2-store systems (only if available):
• TST1T : Temperature store 1 top
• TST1B : Temperature store 1 base
• TST2T : Temperature store 2 top
• TST2B : Temperature store 2 base
TST (1, 2)B, TST (1)T
Store temperatures
Display range
:
-40 ... +260°C
Note:
The values and adjustment channels shown
depend on the selected system, the functions
and options and will only be displayed in the
expert level.
6
Functions and options
6.1
Status level
Displays the current collector temperature.
• TCOL : Collector temperature (1-collector system)
• TCOL1 : Collector temperature 1 (2-collector system)
• TCOL2 : Collector temperature 2 (2-collector system)
Blocking protection
BLPR1(2, 3)
Blocking protection active
Display of blocking protection time
Display of temperatures at S3, S4 and S5
Indicates the current temperature at the corresponding
additional sensor (without control function).
• S3
: Temperature sensor 3
• S4
: Temperature sensor 4
• S5
: Temperature sensor 5
S3, S4, S5
Sensor temperatures
Display range
: -40 ... +260 °C
Note:
Only if temperature sensors are connected, will
S3, S4 and S5 be displayed.
Note:
In systems with return preheating, S3/S5 is used
as the heat source sensor TSTR.
In order to protect the pumps against blocking after stand-
still, the controller is equipped with a blocking protection
function. This function switches on the relays every day at
12:00 a.m. for 10 s at 100%.
TSFB, TRET, TSTR,
TFHQM, TRHQM,
TSFL(VFS),
TSRE (RPS)
Other measured temperatures
Display range: -40 ... +260 °C
Indicates the current temperature at the corresponding
sensor. The display of these temperatures depends on the
system selected.
• TSFB
: Temperature solid fuel boiler
• TRET
: Temperature heating return
• TSTR
: Temperature store return preahting
• TFHQM : Temperature flow (HQM)
• TRHQM : Temperature return (HQM)
Display of further temperatures
Note:
This channel will be displayed only if the blocking
protection is active!