1. INTRODUCTION 

1.1 General Description 

The continuity of electrical power is an essential requirement for critical load 

operations .The Uninterruptible Power System (UPS) is designed to meet the 

user‘s need of present computer, server and the equipment of office 

automation that make the UPS more compact and less noisy. 

To choose the UPS as your equipment protector is a wise investment 

because it supplies reliable, pure and stable power at affordable price. 

1.2 Key features 

1. Multiple microprocessor and double-conversion design base. 

2. Wide input range designed to operate under harsh environment.   

3. High input power factor and DC-start function. 

4. LED and LCD display for detail status and data; real-time alarm silence. 

5. Enhanced protections against light, surges, and disturbance etc. 

6. Remote monitoring with SNMP intelligent slot and RS-232 interface. 

7. Light weight and compact size, easy to transport and place. 

1.3 Important Notices 

To be sure that the UPS will be operated correctly, the following items should 

be noticed: 

1. Read instructions carefully before operating the UPS. 

2. UPS power connect instruction should be followed. 

3. Please don‘t open the case to prevent danger. 

4. If the UPS will be stored for long period, the battery must be charged once 

every 90 days. 

5. Retain the load within the rating of UPS to prevent faults. 

6. Handle unusual events according to the trouble-shooting guide. 

7. Keep the UPS clean and dry. 

 

2. SAFTY INSTRUCTION 

2.1 Transporting 

1. Disconnect all power cables if necessary. 

2. Be careful not to damage the UPS while transporting. 

3. Don‘t move the UPS upside down. 

4. Please transport the UPS system only in the original packaging (to protect 

against shock and impact). 

2.2 Positioning 

1.Do not put the UPS on rugged or declined surface. 

2.Do not install the UPS system near water or in damp environments. 

3.Do not install the UPS system where it would be exposed to direct sunlight 

or near heat. 

4.Do not block off ventilation openings in the UPS system’s housing and don’t 

leave objects on the top of the UPS. 

5.Allow a minimum distance of 10 cm in the rear and two sides of the UPS for 

ventilation. 

6.Keep the UPS far away from heat emitting sources. 

7.Do not expose it to corrosive gas. 

8.Ambient temperature : 0

 - 40

 

2.3 Installation 

1. Connect the UPS system only to an earthed shockproof socket outlet.   

2. Do not connect domestic appliances such as hair dryers or office equipment 

which would overload the UPS system (e.g. laser printers) to UPS output 

sockets. 

3. Place cables in such a way that no one can step on or trip over them. 

Содержание CPO-S1000

Страница 1: ...O S1000R CPO S2000R CPO S3000R Uninterruptible Power Supply 1 CONTENTS 1 INTRODUCTION 1 2 SAFTY INSTRUCTION 2 3 SYSTEM DESCRIPTION 4 4 CABLE CONNECTION 7 5 OPERATION 8 6 TROUBLE SHOOTING GUIDE 13 7 OP...

Страница 2: ...er 4 If the UPS will be stored for long period the battery must be charged once every 90 days 5 Retain the load within the rating of UPS to prevent faults 6 Handle unusual events according to the trou...

Страница 3: ...nt Please take the precautionary measures specified below and any other measures necessary when working with batteries remove wristwatches rings and other metal objects use only tools with insulated g...

Страница 4: ...shutdown or over temperature 6 Warning LED yellow To indicate the UPS is in the status of overload bypass and battery back up 7 Normal LED green To indicate the UPS is operating normally 3 2 Outline D...

Страница 5: ...9 RS 232 Interface Port 6 Remote Control Mini LCD for LED panel only Option 2 SNMP Intelligent Slot Option 7 Fan 3 Fax Modem Surge Protection 8 External Battery Socket 4 Remote Control Detachable LCD...

Страница 6: ...ker 5 External Battery Socket 10 Output Socket NEMA or IEC 11 2KVA 3KVA Tower Case 1 DB 9 RS 232 Interface Port 7 External Battery Socket 2 SNMP Intelligent Slot Option 8 Remote Control Mini LCD for L...

Страница 7: ...e the nominal amperage of your incoming feeder 3 Inspect the packaging carton and its contents for damage Please inform the transport agency immediately should you find signs of damage Please keep the...

Страница 8: ...beeps twice the UPS will start up and Normal LED lights up to indicate the power is from its inverter to the load 3 When the UPS on off Control Key and the LCD Select Up key are pressed simultaneousl...

Страница 9: ...and HI high In this screen press on off Control Key to enter the following steps for LO HI voltage setting B The cursor will pop up to indicate the item newly selected Press on off Control Key to get...

Страница 10: ...ING GUIDE 6 1 UPS Status and Action The description of the following guideline may be helpful in problem solving 1 LED and LCD status as below UPS STATUS AC utility power is normal UPS is running norm...

Страница 11: ...LED and LCD status as below UPS STATUS AC utility power is normal but the load is supplied by AC utility power via bypass Output power is more than 150 referring to the Output Power Menu Warning LED...

Страница 12: ...ill restart up when AC utility power is restored If AC utility power failure is more than 6 hours please follow storage instruction 23 7 OPERATION MODES OF THE UPS 7 1 UPS System Block Diagram 7 2 Nor...

Страница 13: ...o communicate with the computer Its major functions are as follows 1 To broadcast a warning when power fails 2 To close any open files before the battery exhausted out 3 To turn off the UPS 2 Supply R...

Страница 14: ...d discharge Transfer Time AC fail 0 ms 2 5ms typical from inverter to bypass and vice versa Battery Battery low shutdown and Fuse Overload 125 150 30sec then switch to bypass and auto re transfer 150...

Страница 15: ...76V 253V 20V re settable via LCD panel Transfer Time AC fail 0 ms 2 5ms typical from inverter to bypass and vice versa Battery Mode Beeping every 4 seconds re settable and per second when battery low...

Отзывы: