Citizen REF CH-452 Скачать руководство пользователя страница 8

- Eng 14 -

- Eng 15 -

•  Press the “START/STOP” switch to 

turn the monitor off.

*  When you want to stop measurement, 

press the “START/STOP” switch. The 
cuff is deflated and measurement 
stops.

5

 Finishing measurement.

START/STOP Switch

Deutsch

English

Español

Português

Italiano

中文

Français

English

Español

Português

Deutsch

中文

Français

Italiano

4

     is displayed soon after 

pressurization is complete, and 
measurement begins automatically.
*  If the unit judges that pressurization 

is insuf

fi

 cient, it automatically 

repressurizes.

5

 

 blinks each time a pulse is 

detected, and the pressure value 
is displayed on the diastolic blood 
pressure display.

6

  Once measurement is complete, the 

cuff de

fl

 ates and the measurement 

results (systolic/diastolic blood 
pressure values, pulse) are displayed.
*  Systolic/diastolic blood pressure values 

(two seconds) and pulse (one second) 
are displayed alternately.

*  Provided there is no error in the 

measurement results, they are stored 
automatically.

MEASURING YOUR BLOOD PRESSURE

MEASURING YOUR BLOOD PRESSURE

•  Plug the air hose connector 

fi

 rmly into the air hose 

socket on the main unit, as 
illustrated.

2

  Plug the air hose 

connector into the main 
unit.

3

  Place the cuff at the height of the heart.

4

  Press the START/STOP switch (the blue switch).

*  If the pressurization value exceeds 280 mmHg, if pressurization feels 

abnormal, or if you want to stop the measurement process, press the 
START/STOP switch again. The cuff de

fl

 ates, and the power turns off.

1

  All digits on the display blink for 

approximately one second.

• 

All digits displayed is an initial 
display, indicating that the monitor is 
functioning normal.

 The  mark will also be displayed but 

this does not indicate that the battery 
needs to be replaced.

2

 

 is displayed for approximately one 

second.

3

  The cuff is pressurized automatically.

Air hose connector

Air hose socket

Содержание REF CH-452

Страница 1: ...INSTRUCTION MANUAL FOR DIGITAL BLOOD PRESSURE MONITOR REF CH 452 1202 English English...

Страница 2: ...dings 10 Emotional stress tends to cause your blood pressure to rise To obtain correct blood pressure measurements 1 Take five or six deep breaths and then relax before measuring your blood pressure I...

Страница 3: ...ld result in a malfunction 14 If you use a cardiac pacemaker consult your physician before using the monitor 15 Be sure to use this unit only for measuring blood pressure DO NOT use it for any other p...

Страница 4: ...ice is generally recommended to have the monitor inspected every two years to ensure correct functioning and accuracy Please contact a distributor Name CITIZEN SYSTEMS JAPAN CO LTD Address 6 1 12 Tana...

Страница 5: ...sch Fran ais Italiano IDENTIFICATION OF PARTS Air hose connector Air hose Cuff Blue marker Metal hoop IDENTIFICATION OF PARTS Component names START STOP Switch w Stand by Systolic blood pressure displ...

Страница 6: ...ing of used batteries comply with governmental regulations or environmental public institution s rules that apply in your country area 3 Close the battery cover Fitting the lugs of the cover at the ma...

Страница 7: ...G YOUR BLOOD PRESSURE 3 Adjust the position of the cuff so that the blue marker is located in the center of your arm and the hem of the cuff is 1 2 cm for Cuff 2 3 cm for Large Cuff above your elbow T...

Страница 8: ...ds and pulse one second are displayed alternately Provided there is no error in the measurement results they are stored automatically MEASURING YOUR BLOOD PRESSURE MEASURING YOUR BLOOD PRESSURE Plug t...

Страница 9: ...r body or talk during measurement Relax yourself to avoid placing pressure on the cuff You may use your right arm to measure your blood pressure Blood pressure value is likely to differ by as much as...

Страница 10: ...g and holding the MEMORY switch CALLING UP THE DATA STORED IN MEMORY CALLING UP THE DATA STORED IN MEMORY HOW TO CALL UP THE DATA 3A indicating the average value appears on the left section of the dis...

Страница 11: ...Contraction Artery Left atrium Left ventricle Normal state is restored to the artery wall Dilation Systolic blood pressure Diastolic blood pressure Time of day Blood pressure value mmHg 160 140 120 10...

Страница 12: ...A Your blood pressure may vary due to exercise the ambient temperature or your mental state When you have a physician or nurse measure your blood pressure the pressure value is likely to be 10 to 20...

Страница 13: ...nganese Approx 300 times Automatic Power Off function Approx 3 min after activated Dimensions 130 W x 53 H x 118 D mm Weight Approx 240 g w o batteries cuff approx 130 g Operating conditions Temperatu...

Страница 14: ...Design and Specification are subject to change without notice CITIZEN is a registered trade mark of Citizen Holdings Co Ltd Japan...

Отзывы: