SPECIFICATIONS

Model Number:

CH-452

Measurement system:

Oscillometric method

Measurement Localization

Upper Arm

Cuff:

Soft cuff

Arm circumference range:

22.0 to 32.0 cm

Measurement range:

Pressure

0 to 280 mmHg

Pulse

40 to 180 pulse/min

Accuracy:

Pressure

±3 mmHg

Pulse

±5% of reading

LCD displays:

Pressure

3 digits

Pulse

3 digits

Icons

: Measurement icon, 

:Battery icon

Switch:

2 (START/STOP, MEMORY)

In

fl

 ation:

Automatic in

fl

 ation by internal pump

De

fl

 ation:

Automatic speed de

fl

 ation system.

Rated voltage:

6 V DC  

 3 W (

 : direct current)

Exhaust:

Electromagnetic quick exhaust valve

Power supply:

4 AA  batteries (R6P, LR6) 

Battery duration:

Alkaline

Approx. 1000 times

(170 mmHg, once/day, 
23°C)

Manganese

Approx. 300 times

Automatic Power Off function:

Approx. 3 min. (after activated)

Dimensions:

130 (W) x 53 (H) x 118 (D) mm

Weight:

Approx. 240 g w/o batteries   cuff: approx. 130 g

Operating conditions:

Temperature

10°C to 40°C

Humidity

30% to 85% RH

Storage conditions:

Temperature

-20°C to 60°C

Humidity

10% to 95% RH

Electric shock protection:

Internal power unit

Degree of Protection

 Type BF applied part

Mode of operation:

Continuous operation

Protection against ingress of water:

IPX0

Service Life:

5 years

Cuff’s Life:

Approx. 2000 times

Accessories

Set includes a cuff, 4 AA batteries (R6P) for the 
monitor, Instruction Manual.

Optional Accessories:

Large Cuff 32.0 – 42.0 cm

* Applied part for this device is Cuff.
* A range in barometoric pressure 105 kPa to 70 kPa
* A range in altitude -300 m to 3000 m
*  Overall system accuracy of this device is met with the requirement of item 7.9 of EN1060-3.

EN1060-3 : Non-invasive sphygmomanometers Part 3 (European Standard)

Содержание REF CH-452

Страница 1: ...INSTRUCTION MANUAL FOR DIGITAL BLOOD PRESSURE MONITOR REF CH 452 1202 English English...

Страница 2: ...dings 10 Emotional stress tends to cause your blood pressure to rise To obtain correct blood pressure measurements 1 Take five or six deep breaths and then relax before measuring your blood pressure I...

Страница 3: ...ld result in a malfunction 14 If you use a cardiac pacemaker consult your physician before using the monitor 15 Be sure to use this unit only for measuring blood pressure DO NOT use it for any other p...

Страница 4: ...ice is generally recommended to have the monitor inspected every two years to ensure correct functioning and accuracy Please contact a distributor Name CITIZEN SYSTEMS JAPAN CO LTD Address 6 1 12 Tana...

Страница 5: ...sch Fran ais Italiano IDENTIFICATION OF PARTS Air hose connector Air hose Cuff Blue marker Metal hoop IDENTIFICATION OF PARTS Component names START STOP Switch w Stand by Systolic blood pressure displ...

Страница 6: ...ing of used batteries comply with governmental regulations or environmental public institution s rules that apply in your country area 3 Close the battery cover Fitting the lugs of the cover at the ma...

Страница 7: ...G YOUR BLOOD PRESSURE 3 Adjust the position of the cuff so that the blue marker is located in the center of your arm and the hem of the cuff is 1 2 cm for Cuff 2 3 cm for Large Cuff above your elbow T...

Страница 8: ...ds and pulse one second are displayed alternately Provided there is no error in the measurement results they are stored automatically MEASURING YOUR BLOOD PRESSURE MEASURING YOUR BLOOD PRESSURE Plug t...

Страница 9: ...r body or talk during measurement Relax yourself to avoid placing pressure on the cuff You may use your right arm to measure your blood pressure Blood pressure value is likely to differ by as much as...

Страница 10: ...g and holding the MEMORY switch CALLING UP THE DATA STORED IN MEMORY CALLING UP THE DATA STORED IN MEMORY HOW TO CALL UP THE DATA 3A indicating the average value appears on the left section of the dis...

Страница 11: ...Contraction Artery Left atrium Left ventricle Normal state is restored to the artery wall Dilation Systolic blood pressure Diastolic blood pressure Time of day Blood pressure value mmHg 160 140 120 10...

Страница 12: ...A Your blood pressure may vary due to exercise the ambient temperature or your mental state When you have a physician or nurse measure your blood pressure the pressure value is likely to be 10 to 20...

Страница 13: ...nganese Approx 300 times Automatic Power Off function Approx 3 min after activated Dimensions 130 W x 53 H x 118 D mm Weight Approx 240 g w o batteries cuff approx 130 g Operating conditions Temperatu...

Страница 14: ...Design and Specification are subject to change without notice CITIZEN is a registered trade mark of Citizen Holdings Co Ltd Japan...

Отзывы: