37
Starting registering the printer command and flash memory/ ESC~CS
[ASCII]
ESC
~ C S n1 n2 d1 d2
…
dn
[Decimal]
27 126 67 83 n1 n2 d1 d2
…
dn
[Hexadecimal]
1B 7E 43 53 n1 n2 d1 d2
…
dn
[Description]
●
Registers a series of printer commands in the flash memory.
●
{d1 d2 ... dn} is a data string to be registered.
●
n1 and n2 indicate the number of data to be registered. Divide the number of data to be registered by 256
and specify its remainder in n1, its quotient in n2.
●
For registering several command groups, send the command groups consecutively. Registration is
completed upon receive of the command group with the number of data = 0.
ESC~CS
n1 n2 d1 d2 … dn
←
Command group 1
n1 n2 d1 d2 … dn
←
Command group 2
00
←
‘Number of data = 0’ command group
●
Command groups are assigned with a number in sending order from 0 before registered. Up to No. 255 can be
registered (total number of registration: 256). Specify this number to call out a given command.
●
When a new registration begins, data that have been previously registered in the flash memory will be all deleted.
●
A registration area up to 64KB (64 × 1024 = 65536 bytes) is available.
[Caution]
●
Do not register ESC~CS command in the registration command group.
●
When calling out another command group with ESC~CL from the registration command group, be sure to
register ESC~CL command at the end of the command group. Otherwise, print result cannot be assured.
Registration area = (Management domain) + (Raw-data domain)
Management domain: 4 × 256
Raw-data domain: 65536 – (Management domain) – 1 = 64511