7.3.2 Data Configuration
t
Mark
b
0
, b
1
, b
2
,.........
Space
(1)
(2)
(3)
(1) Start Bit
(2) Data Bit (+ Parity Bit)
(3) Stop Bit (1 or More)
(1) Start bit
In 1/2 bit from the Mark-to-Space starting edge, state is read once again. When "Space" state is
confirmed, it is recognized as the start bit. If it is "Mark" state, it is not taken as the start bit. Without
taking it as an error, detection of a start bit is carried out once again.
(2) Data Bit + Parity Bit
Data bit and parity bit are sampled at 1/2 start bit for time length equal to 1 bit. The state thus sampled is
taken as the data for the bit concerned. Bits are named as Bit 0, Bit 1, ..., parity bit counted from the one
close to the start bit.
(3) Stop bit
The stop bit is a mark level of 1 bit or more. With "Space" having been detected on detection of a stop
bit, framing error takes place.
Содержание iDP-3310
Страница 1: ...SERIAL THERMAL PRINTER MODEL iDP3310...
Страница 19: ...iDP3310 User s Manual 6 CITIZEN 2 3 3 Head and Cutter Layout...
Страница 20: ...iDP3310 User s Manual 7 CITIZEN 3 OUTER APPEARANCE AND COMPONENT PARTS 3 1 Outer Appearance and Component Parts...
Страница 64: ...iDP3310 User s Manual 51 CITIZEN 11 CHARACTER CODES TABLE 11 1 P 250 P 900R mode...
Страница 65: ...iDP3310 User s Manual 52 CITIZEN 11 2 iDP 562 mode...
Страница 66: ...iDP3310 User s Manual 53 CITIZEN 11 3 International Character Codes Table All Common...
Страница 67: ...iDP3310 User s Manual 54 CITIZEN APPENDIX 1 BLOCK DIAGRAM...
Страница 68: ...iDP3310 User s Manual 55 CITIZEN APPENDIX 2 OUTER DIMENTION...
Страница 69: ...iDP3310 User s Manual 56 CITIZEN German...