Citizen CT830 Скачать руководство пользователя страница 7

English

- Eng 7 -

3.  The room temperature is renewed every minute.
    After measuring body or material surface temperature, the 

sensor may be warm which may affect the room temperature 
reading. Therefore during the fi rst 15 minutes after every use, 
the room temperature on the display may be inaccurate.

MATERIAL SURFACE TEMPERATURE / STOP WATCH

1.  Make sure that the probe lens is clean.
2. Press 

ON/MEM

 button to enter the EAR TEMPERATURE 

mode.

3.  MATERIAL SURFACE TEMPERATURE:
 

Press and hold the 

ON/MEM

 button and then press the 

SCAN

 button once to leave the EAR EMPERATURE mode 

and enter the MATERIAL SURFACE TEMPERATURE scan 
mode with 

 icon (Fig.10).

Fig.10

(Material surface temperature mark)

3.1  Aim the probe torward the material and press the 

SCAN

 button, and the material surface temperature 

appears on the display. To measure the temperature 
of another material, repeat the procedure. If the 

SCAN

 

button is pressed and held, the measurement reading 
will be continuously updated.

3.2  Applications include temperature measurements for 

water, milk, cloth, etc.

Press and hold the 

ON/MEM

 button and then press 

the 

SCAN

 button once to leave MATERIAL SURFACE 

TEMPERATURE mode and enter the STOPWATCH mode 
with the 

 icon (Fig.11).

NOTE:

  *  Do NOT submerge the probe tip in liquid.

 

*  This mode shows the surface temperature of material only and 

is NOT for taking human body temperature.

Содержание CT830

Страница 1: ...INSTRUCTION MANUAL for DIGITAL EAR THERMOMETER REF CT830 Probe Probe Cap ON MEM button LCD SCAN button Probe lens IDENTIFICATION OF PARTS Fig 1 English 0801...

Страница 2: ...on on or in the ear 4 DO NOT use the ear thermometer if the main body is damaged for example the probe lens is broken The continuous use of a damaged unit may cause injury improper results or serious...

Страница 3: ...and do NOT allow the unit to come into contact with chemical solvents 4 Do NOT drop the ear thermometer and do NOT expose the ear thermometer to heavy shock The ear thermometer is not shock protected...

Страница 4: ...erature so you can compare it to the measurement result About Ear Thermometers All objects radiate heat To measure body temperature this ear thermometer uses an infrared sensor incorporated in its pro...

Страница 5: ...n for about 5 sec and the icon starts to ash indicating the setting mode Fig 5 Fig 5 Date Time 24 12 hour display 2 Press the SCAN button for the 12 24 hour setting mode The icon starts to ash indicat...

Страница 6: ...emove the probe and read the temperature on the display Fig 8 Fig 8 Ear temperature mark NOTE The time and calendar settings should be done before measurement readings are taken The thermometer always...

Страница 7: ...the MATERIAL SURFACE TEMPERATURE scan mode with icon Fig 10 Fig 10 Material surface temperature mark 3 1 Aim the probe torward the material and press the SCAN button and the material surface temperatu...

Страница 8: ...eps to warn the user of a fever MEMORY There are a total of 9 memory slots for recording EAR TEMPERATURE measurements Each memory slot also records the date and time of the measurement Memory slots ca...

Страница 9: ...NG on the display except the time and date When the ON MEM button is pressed NOTHING is displayed except the battery mark blinking 12 times followed by OFF for 1 second and then the display returns to...

Страница 10: ...oo long may cause the probe to make a higher ambient temperature reading This could make the body temperature measurement lower than usual After each use clean the probe and probe lens with a cotton s...

Страница 11: ...sert it If the message reappears contact the retailer where you purchased the thermometer for service 1 Ear temperature mode Temperature taken is higher than 42 2 C 108 F 2 Material surface temperatur...

Страница 12: ...Q4 Is it hygienically safe to use the ear thermometer without the probe cover A4 The probe and probe lens should be kept clean by using a cotton swab or soft cloth moistened with 70 alcohol Therefore...

Страница 13: ...ent Operating temperature range 10 40 C 50 104 F Storage temperature range 20 50 C 4 122 F Transportation temperature range must be less than 70 C Unit size 115 L X 37 W X 29 H mm Weight Approx 60g in...

Страница 14: ...Prob Prob IDE Design and Specification are subject to change without notice CITIZEN is a registered trademark of Citizen Holdings Co Japan CITIZEN es una marca registrada de Citizen Holdings Co Jap n...