— 28 —
ESC S n
[Function]
Setting serial interface communication speed
[Code]
<1B>H<53>H<n>
[Range]
{0 =< n =< 6(Hex)}
{30 =< n =< 36(Hex)}
[Outline]
Sets the communication speed for the serial interface.
The command is valid only when the printer is connected through a serial cable. It is
not valid when using IrDA interface. The last setting is valid even after the printer is
switched OFF.
[Default]
The default value is 3 [9600 BPS]
ESC T
[Function]
Printing Diagnostic information
[Code]
<1B>H<54>H
[Outline]
Prints current printer attributes and diagnostics.
[See Also]
ESC .
[Print Results]
CITIZEN
Mobile Printer
/////////////////////////////////////////////
Model CMP-10 Ver x.xxXX
Intensity:
100%
Timeout:
10 min
Temperature:
27°C
Battery:
7.5V [**...]
Mode:
RS232
Speed:
9600 bps
Switches:
0 0 0 0 0 0 0 0
n (Hex)
Speed (bps)
0, 30
1200
1, 31
2400
2, 32
4800
3, 33
9600
4, 34
19200
5, 35
57600
6, 36
115200
7, 37
38400 (Firmware 2.04 or later)