6
5.6
Rest Period
Continuous operation of this machine can be accomplished when volume is set at the 3
o’clock position. If dial is set for full output or blast, 30 minutes is the maximum time of
haze ability before a 3-minute rest period for reheating is necessary. If you wait a full 10
minutes, you will be able to haze again for at least 30 minutes on full.
5.7
Shut down
When finished with the machine, clean the tube and pump by operating the unit while
running a pint of 5% vinegar/distilled water mix through the pump and then rinse with a
pint of distilled water. This will keep the piston in the pump from becoming stuck and not
working. When finished, water should remain in the line for storage. Do not drain or
empty the tube of water.
5.8 Troubleshooting
1.
If the pump does not draw fluid
If the pump does not draw fluid into the hazing unit, be sure the unit is warm and ready to
operate. Then check to see that the tubing is in the fluid, not above the fluid. Check
electrical power to the machine. Hold up tubing, remove filter and push, blow or use a
turkey baster to force the fluid inside the pump. Try again to see if it will pump now.
Check to hear any sound coming from the pump side (nearest the top). A slight vibrating
sound should be heard if the pump is pumping fluid. A loud knocking sound will be heard
if only air is in the line and fluid has not come in yet. Force fluid through the line to get it
started. This is called “priming” and the line needs to be full of fluid for the haze
mechanism to work.
Note: Do not run the pump without fluid passing through the
tube. This will cause the pump to become hot and could damage the piston. This
is not covered under warranty.
2.
If Ready Light Does Not Come On
If you are not a factory-authorized dealer, this is the only owner-permitted troubleshooting
step that will not void the warranty. If the green ready light does not come on after warm-
up, this may possibly indicate the unit has overheated. This may happen if there is not
enough air circulation or if it is in a closed area. The machine needs to be air cooled if
this occurs. If the green ready light stays off, this indicates the heat safety breaker has
released. It will not reset until the unit has cooled to 169
o
F (76
o
C) Then when you reset,
it will be ready to use again. Plug in the unit and warm it up again. The green ready light
should come on after 10 minutes. Call your dealer if this does not solve the problem.