Opening Unit 

 

Remove the four plastic screws to open the unit. The printed circuit board 

contains static sensitive parts, so the installer should wear a grounding strap 

when handling the board. 

Enclosure Mounting 

 

IMPORTANT: 

This unit contains two enclosures. The larger one contains the 

electronics  (VAS  -  4)  and  the  smaller  one  contains  the  sensor.  The  two 

enclosures are permanently connected together by a low voltage wire. The 

sensor enclosure contains an oil based protection device that is filled with a 

special fluid. The protection device has a cap over the ¼" fitting to prevent the 

oil  from  leaking  out  during  shipping  and  installation. 

THE  SENSOR 

ENCLOSURE MUST BE MOUNTED IN AN UPRIGHT POSITION  TO 

PREVENT  THE FLUID FROM  LEAKING OUT. 

Once  the unit  is  securely 

mounted in an upright position, the cap over the ¼" fitting can be removed. 

 

The recommended mounting method for the VAS - 4 is to use four mounting 

holes located where the 4 plastic screws are that hold down the lid. Use the 

box as a template for mounting (see Fig. 2). 

 

NOTE: THE VAS - 4 SHOULD NOT BE MOUNTED WHERE SUNLIGHT 

CAN DIRECTLY ENTER THE TRANSPARENT COVER. 

 

The printed circuit board is designed to have power come ln from the bottom 

of  the  box.  Remove  the  knockouts  that  are  needed  for  power  entry.  Two 

watertight fittings are provided for the power and alarm line. If the board must 

be removed to install a watertight fitting, care must be taken in handling the 

board. 

NOTE: IF YOU RUN CONDUIT INTO THE BOX AND DO NOT USE THE 

WATERTIGHT  FITTINGS,  YOU  MUST  USE  A  SEALANT  TO  SEAL 

AROUND THE CONDUIT CONNECTION

 

Install the printed circuit board after the connectors have been installed. Use 

the four #6 screws provided to mount the board in the box and tighten only to 

a snug fit. 

DO NOT OVER TIGHTEN (see Fig. 2) 

Содержание Superior VAS-4

Страница 1: ...l Revision 0 01 July 2020 Chemical Injection Technologies Inc 835 Edwards Road Fort Pierce FL 34982 Tel 772 461 0666 Fax 772 460 1847 Superior chlorinators com www chlorinators com Bulletin 4018 Pub N...

Страница 2: ...ening Unit 5 Enclosure Mounting 5 Installing Vacuum Hose 6 Installing Power Alarms 6 Section 6 Set Up and Calibration 6 Delay Timer Adjustment 6 Low Level Adjustment 7 High Level Adjustment 7 Alternat...

Страница 3: ...timer The enclosure has a NEMA 4X rating therefore it can be mounted outside Applications include loss of chlorinating in water and wastewater treatment pool pump monitoring automotive test equipment...

Страница 4: ...0 to 30 inHg Low Alarm Range 0 to 15 inHg High Alarm Range 15 to 30 inHg Over Pressure 50 PSI Delay Timer 1 to 100 sec Analog output Voltage 0 to 3 VDC Current 0 to 3 ma DC Reset Switch IP 65 protecti...

Страница 5: ...ime Latch LED Indicator When either the high or low indicators are active this starts the delay timer If the alarm is active longer than the preset delay time then the latch LED indicator will become...

Страница 6: ...Latch Alarm Relay When either the High or Low Alarm relays become active and the delay time is over the latch alarm relay also becomes active This is indicated by the Latch Alarm indicator This relay...

Страница 7: ...ght position the cap over the fitting can be removed The recommended mounting method for the VAS 4 is to use four mounting holes located where the 4 plastic screws are that hold down the lid Usethe bo...

Страница 8: ...ikes or other power surges The alarms can be hooked up in many ways Be sure the relay specifications are not exceeded The relay outputs are labeled HIGH ALARM LOW ALARM and LATCH ALARM Remember the la...

Страница 9: ...Hg and MAX 30 inches of Hg NOTE If you want to disable the high alarm turn the pot clockwise until it stops Alternate Method for Accurate High Low Level Adjustment If a high degree of accuracy is req...

Страница 10: ...looked at from the middle of the board is rotated all the way to the right and the other pot is rotated to approximately the 12 00 position The pot that is close to the 12 00 position is the pot to ad...

Страница 11: ...ofollow instructions supplied with the product c Repair or attempted repair by anyone not authorized byTHE MANUFACTURER d Any shipment of the product e Any other causes which do not relate to a produc...

Страница 12: ...10...

Страница 13: ...11...

Страница 14: ...VAS 4 VACUUM MONITORING SYSTEM Chemical Injection Technologies Inc 835 Edwards Road Fort Pierce FL 34982 Tel 772 461 0666 Fax 772 460 1847 Superior chlorinators com www chlorinators com...

Отзывы: