Steam Piping Installation Instructions

1. Set and anchor dryer in position.  Machine should be level to

assure proper steam circulation.

2. To prevent condensate draining from headers to dryer, piping

should have a minimum 12" (305 mm) above respective
header.  Do not make steam connection to header with a
horizontal or downwardly facing tee or elbow.

3. Whenever possible, horizontal runs of steam lines must drain,

by gravity, to respective steam header.  Water pockets, or an
imporperly drained steam header will provide wet steam,
causing improper operation of dryer.  If pockets or improper
drainage cannot be eliminated, install a by-pass trap to drain
condensate from the low point in the steam supply header to
the return.

4. In both steam supply and steam retyrn line, it is recommended

that each have a 3/4" (DN 20) union and 3/4" (DN 20) globe
valve.  This will enable you to disconnect the steam
connections and service the dryer while your plant is in
operation.

5. Before connecting trap and check valve to dryer, open globe

valve in steam supply line and allow steam to flow through
dryer to flush out any dirt and scale from dryer. This will
assure proper operation of trap when connected.

6. After flushing system, install bucket trap (with built-in

strainer) and check valve.  For successful operation of dryer,
install trap 18" (457 mm) below coil and as near to the dryer
as possible.  Inspect trap carefully for inlet and outlet
markings and install according to trap manufacturer's
instructions.  If steam is gravity returned to boiler, omit trap
but install check valve in return line near dryer.

7. Install union and globe valve in return line and make final

pipe connections to return header.

STEAM  PIPING
INSTALLATION
INSTRUCTIONS

Содержание L28UR30E

Страница 1: ...T OWNER THIS MANUAL MUST BE GIVEN TO THE EQUIPMENT OWNER THIS MANUAL MUST BE GIVEN TO THE EQUIPMENT OWNER THIS MANUAL MUST BE GIVEN TO THE EQUIPMENT OWNER THIS MANUAL MUST BE GIVEN TO THE EQUIPMENT OW...

Страница 2: ...occupants Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department Installation and service mus...

Страница 3: ...e touchez a aucun interrupteur Ne pas vous servir des telephones se trouvant dans le batiment ou vous vous trouvez Evacuez la piece le batiment ou la zone Appelez immediatement votre fournisseur de ga...

Страница 4: ...s wrinkles from setting in and reduces the possibility of spontaneous combustion WARNING Be safe shut main electrical power and gas supply off externally before attempting service WARNING Never use dr...

Страница 5: ...move or install to diagnose troubles to adjust remove or replace defective equipment or a part nor does it include any responsibility for transportationexpensewhichisinvolvedtherein ThewarrantyofCisse...

Страница 6: ...24 25 DryerInstallationwithSeparateExhaust 26 Make Up AirRequirements 2 7 ExhaustandVenting 2 8 RulesforSafeOperationofDryer 2 9 OperatingInstructions CoinMeterModels 30 33 PAGE Service Savers 34 Tro...

Страница 7: ...arrage Start arranquedeunmovimiento emission of heat in general mission de chaleur en general Warmeabgabeallgemein emisi ndecalor cooling refroidissement K hlen enfriamiento dangerousvoltage tensionda...

Страница 8: ...euxsens DrehbewigunginzweiRichtungen movimientorotativoenlosdos sentidos End of Cycle caution attention Achtung atencion precaucion directionofrotation sens de mouvement continu de rotation Drehbewegu...

Страница 9: ...free access to the rear of dryer for future servicing of belts pulleys and motors Installation clearance from all combustable material is 0 ceiling clearance 0 rear clearance and 0 side clearance Bef...

Страница 10: ...Page 10 L28UR30 Outline Dimensions Gas Steam and Electric Models...

Страница 11: ...Page 11 L28US30 Outline Dimensions Gas Model...

Страница 12: ...t Weight 495 lb 225 kg approx Domestic Shipping Weight 526 lb 239 kg approx 1 carton Export Shipping Weight 664 lb 301 kg approx 1 box Maximum Air Displacement 700 cfm 1190 m h Recommended Operating R...

Страница 13: ...rton Export Shipping Weight 526 lb 239 kg approx 1 box Export Shipping Dimensions 74 L 1880 mm x 35 W 889 mm x 55 H 1397 mm Maximum Air Displacement 700 cfm 1190 m h Recommended Operating 530 630 cfm...

Страница 14: ...TR300 115 200 240 60 1 1 2 37 6 2 3 1 1725 MTR300 200 240 50 1 1 2 37 3 7 1425 MTR214 208 230 460 60 3 1 2 37 2 5 1 1 1725 MTR302 200 240 346 415 50 3 1 2 37 2 0 1 0 1425 MTR302 220 380 60 3 1 2 37 1...

Страница 15: ...ld be removed daily or as required to prevent an over accumulation Permanent press durable press and other modern day fabrics require the care that your laundry dryers now provide At the end of the dr...

Страница 16: ...vice connection box on the rear of the dryer Do not change wiring without consulting factory as you may void the factory warranty Do not connect the dryer to any voltage or current other than that spe...

Страница 17: ...line If gravity return to boiler omit trap 3 Insulate steam supply and return line for safety of operator and safety while servicing dryer 4 Keep dryer in good working condition Repair or replace any...

Страница 18: ...Check the altitude of dryer 4 Check with utilities company for proper gas pressure and gas supply line 5 Natural gas only check the gas pressure inlet supply to dryer 11 inches 27 mbar water column ma...

Страница 19: ...piping system during any pressure testing of that system at test pressures in excess of 1 2 psi 3 5 kPa The dryer must be isolated from the gas supply piping system by closing it s individual manual...

Страница 20: ...nces should be connected upstream from the loop WARNING LIQUIFIEDPETROLEUMGASESONLY A gas pressure regulator for liquified petroleum gases is not furnished on gas heated clothes dryers This regulator...

Страница 21: ...00000 330000 350000 380000 400000 430000 450000 480000 504000 550000 605000 650000 705000 750000 806000 850000 907000 960000 1000000 3 4 3 4 3 4 3 4 3 4 3 4 1 1 1 1 1 4 1 1 4 1 1 2 1 1 2 1 1 2 2 2 2 2...

Страница 22: ...n line it is recommended that each have a 3 4 DN 20 union and 3 4 DN 20 globe valve This will enable you to disconnect the steam connections and service the dryer while your plant is in operation 5 Be...

Страница 23: ...Page 23 Steam Piping Installation Illustration...

Страница 24: ...S30 L36US36 L44FD42 MODELS L28CD30 L28UR30 L36CD30 L36UR30 L36UR36 L36AR36 L44FD42 MODELS L44CD42 L50CD42 No of dryers Duct diameter in inches in cm No of dryers Duct diameter in inches in cm No of dr...

Страница 25: ...inute cfm used 4 Zero inches clearance to combustible material allowed on sides and at points within 4 inches 100 mm of front on top 5 Heat loss into laundry room from dryer fronts only is about 60 Bt...

Страница 26: ...enclosure from the top or side walls See Dryer Make up Air Requirements Chart 2 Enclosure plenum with service door This separates the dryer air from the room comfort air If dryers use room air instead...

Страница 27: ...C 125 125 56 7 2000 3400 12 305 384 2477 C 150 150 68 2250 3825 12 305 432 2787 HD175 175 79 4 2780 4726 12 305 534 3445 HD190 190 86 2 3000 5100 12 305 576 3716 WMC HD20 20 9 1 450 765 6 153 87 561...

Страница 28: ...se 2 feet 0 6 m of straight duct on dryer before installing an elbow on Energy Saver models only 5 Do not install wire mesh or other restrictions in the exhaust duct 6 Use clean outs in the exhaust du...

Страница 29: ...arnings or precautions 7 Never tumble fiberglass materials in the dryer unless the labels say they are machine dryable Glass fibers break and can remain in the dryer and could cause skin irritation if...

Страница 30: ...ature heavy fabrics and hard to dry cottons and linens MEDIUM 150 F 66 C exhaust temperature permanent press synthetic blends LOW 135 F 57 C exhaust temperature delicate sheer fabrics 4 Press the Star...

Страница 31: ...yerisdesignedforacapacitymaximumload Overloading itwillresultinlongerdryingtimeanddampspotsonsomeofthe load Maximumoperatingefficiencydependsonproperairflow The lint screen must be kept clean daily to...

Страница 32: ...Page 32 Setting Time On Computerized Coin Meter Illustration COMPUTERIZED COIN METER DIP Switch Banks are located here...

Страница 33: ...me minutes asshown 3 To set the time on the DIP bank simply set the appropriate switch to the ON up position to total the desired amount of time NOTE OFF down position equals 0 minute EXAMPLE 25 for12...

Страница 34: ...main gas line turned on 3 Check for low or intermittant gas pressure 4 Check spark ignition module diagnostic light CLOTHES ARE NOT SATISFACTORILY DRY 1 Timed cycle Did you allow enough heating time b...

Страница 35: ...eck with local power company for recommended corrective measures Check with local power company to insure that wiring is adequately sized for load Check all electrical connections and tighten any loos...

Страница 36: ...ects lint accumulation or other causes that may prevent damper from opening Check duct work for lint build up Check installa tion sheet to insure that duct work and make up air openings are adequately...

Страница 37: ...Open for blue flame Blow out Adjust gas pressure per rating plate Send to factory for correct orifices Clean exhaust Replace direct spark igniter Replace orifices Check factory for correct size Dryer...

Страница 38: ...hermostat controls operation of solenoid valve If defective replace thermostat Check for inlet and outlet marking on check valve and invert if necessary Remove plug and blow down strainer or remove an...

Страница 39: ...the module has multiple retries and no flame is detected the gas valve is de energized and the module goes into an interpurge delay After this delay the module will attempt another trial for the igni...

Страница 40: ...Page 40 DIRECTSPARK IGNITIONOPERATION FLOW CHART...

Страница 41: ...idler bracket Lubricate idler pulley once every two months using six grams of high temperature grease Do not over grease 5 Electric motor Keep motor clean and dry Motors are packed with sufficient gr...

Страница 42: ...me by following instructions outlined on separate page of this manual 12 Main Basket Bearings Lubricate once every six months using six grams of high temperature grease Do not over grease 13 Steam Hea...

Страница 43: ...T TYPE OF GAS SHUTTER ADJUSTMENT Natural gas 1 2 Open Liquidpetroleum 1 4 Open Manufacturedgas 1 16 Open AIR SHUTTER ADJUSTMENT ProperMethod Close air shutters to yellow tip then open air shutters to...

Страница 44: ...er air inlet shutters are correctly adjusted but air through the dryer is insufficient This condition indicates excessive lint in the lint compartment lack of make up air in the room restricted exhaus...

Страница 45: ...ft Step 4 Remove the nuts and washers holding the flange basket bearing and take it off the dryer Step 5 Inspect the bearings for damage and replace as necessary in reverse order of removing them Befo...

Страница 46: ...diameter pins inside the drying compartment between the rim of the basket opening and the rim of the door opening in the positions shown in figures 1 and 2 Check the two B pins for equal clearance NO...

Страница 47: ...ping the sweep sheet C Mark this position and the nearest rib to this position D Remove the basket do not loosen the alignment bolts E With the basket on the floor spider up place one or two shims bet...

Страница 48: ...sition shown hold switch mounting bracket firmly and adjust switch actuator D with needle nose pliers at E by twisting actuator right or left whichever is needed so that switch closes when end of air...

Страница 49: ...Page 49 30 lb Dryer Front View Illustration...

Страница 50: ...acement Kit 25 TU10284 Lint Trap Front Support 26 TU10177 Spacer 27 TU8457 Thermostat Cover 28 TU9225 Coin Vault Lock and Key 29 TU14602 Front Panel and Door Assembly Specify Color 30 TU2083 Basket We...

Страница 51: ...Page 51 30 lb Dryer Rear View Illustration...

Страница 52: ...1 TU7733 8 x 1 2 Self Drill Screw 2 TU3211 3 8 16 x 2 1 2 Leveling Bolts 3 TU4937 3 8 16 Jam Nut 5 TU4787 3 8 16 Hex Nut 6 VSB134 3 8 Split Lockwasher 7 TU12803 Idler Bracket 8 TU12576 3 8 16 x 1 Car...

Страница 53: ...ntrol 37 SB 00951 0 Screw 8 x 7 16 Phillips 38 CA 13098 0 Gasket Access Door Not Shown 1 TU14662 Logo Decal 2 TU3479 10 32 x 7 16 Truss Head Screw 3 P104 1 4 Cut Washer 4 FB187 10 Lockwasher 5 TU2842...

Страница 54: ...TU3266 Nut 27 SV136 6 32 x 15 16 Truss Head Scr 28 M271 8 Int Tooth Lockwasher 29 SB 00951 0 Screw 8 x 7 16 Phillips 30 CA 13098 0 Gasket Access Door Not Shown Call factory for Coin Meter part number...

Страница 55: ...TU2878 10 x 5 8 Sheet Metal Screw 9 TU5158 Door Catch Assembly 10 TU2236 Hinge Post 11 PIF172 Delrin Bearing Pkg 2 12 TU2090 Basket Door Seal 13 TU4839 10 32 x 3 8 Machine Screw 14 TU7862 Door GLass...

Страница 56: ...3240 SafetyHighLimitThermostat 2 TU3240 185 F 85 C Thermostat 3 TU5150 150 F 66 C Thermostat 4 TU7244 135 F 57 C Thermostat 5 TU5143 MountingBracket 6 TU3624 6 32 x 1 4 Round Head Screw 6 each 7 TU340...

Страница 57: ...l Screw 2 TU8052 Tee 8 x 6 x 6 3 TU8176 Pipe 8 x 17 1 2 4 TU9161 Installation Label 5 TU10268 Elbow 8 6 TU10335 Tee 8 x 6 x 6 7 TU8053 Elbow 6 8 TU8054 Pipe 6 x 15 1 2 9 TU8055 Pipe 6 x 23 1 2 1 F888...

Страница 58: ...d 5 TU2414 3 4 16 x 3 8 Straight Connector 6 TU2405 Steam Coil 9 required 7 3 4 W x 1 5 8 H x 26 L 7 CB36 1 4 20 x 1 2 Hex Head Screw Pkg of 6 8 TU7733 8 x 1 2 S M S Pkg of 6 9 TU2598 Air Filter 16 x...

Страница 59: ...t 8 TU10946 Manifold Plug 9 TU13678 Thermostat Man Reset 300 10 390501053 1 2 Elbow 11 GA 00764 0 Electrode Spark Igniter 12 CB36 1 4 20 x 1 2 Hex Hd Scr 13 TU2846 1 4 Split Lockwasher 14 TU4934 1 4 2...

Страница 60: ...A 00764 0 Electrode Spark Igniter 11 TU13826 Electrode Spark Mounting Plate 12 CB36 1 4 20 x 1 2 Hex Head Screw 13 TU2846 1 4 Split Lockwasher 14 TU2847 1 4 Flat Washer 15 TU4934 1 4 20 Hex Nut 16 TU2...

Страница 61: ...lock D Fuse E Bonnet with Elements F Heater Elements G Motor Fuse 1 TU3103 Bonnet Weldment 2 TU3102 Hold Down Plate 3 TU9205 Control Box Weldment 4 TU9207 Terminal Box Cover 5 TU12454 Top Cover 7 TU31...

Страница 62: ...9143 TU9143 TU9143 TU9142 TU9143 TU9143 TU9143 TU9142 D HeaterFuse Block TU11096 TU11096 TU11096 TU11096 TU9141 TU11096 TU11096 TU11096 TU11096 E HeaterFuses TU7224 40AMPS 3required TU7224 40AMPS 3req...

Страница 63: ...W 480V 3PH 21KW 240 414 3PH 21KW 550V 3PH Heater Amperes Motor Amperes Control Amperes Total Amperes at Rated Voltage 109 AMPS 66 AMPS 62 AMPS 95 AMPS 59 AMPS 55 AMPS 28 AMPS 55 AMPS 25 AMPS Hz 60 60...

Страница 64: ...Page 64...

Отзывы: