![Cisco VG248 - Gateway Скачать руководство пользователя страница 103](http://html.mh-extra.com/html/cisco/vg248-gateway/vg248-gateway_software-configuration-manual_65007103.webp)
6-5
Cisco VG248 Analog Phone Gateway Software Configuration Guide
OL-1209-02
Chapter 6 Troubleshooting the VG248
Troubleshooting Software Errors
Troubleshooting Software Errors
The VG248 displays informational messages and errors on-screen or in the event
log (see the
“Working with the Event Log” section on page 6-22
for details on
accessing the event log), which indicate potential software problems, such as
misconfiguration, time-outs, unreachable servers, and so on.
The following sections provide details about resolving these errors:
•
Resolving Network and System Errors, page 6-5
•
Resolving Analog Errors, page 6-10
•
Resolving Cisco CallManager Errors, page 6-11
Resolving Network and System Errors
Table 6-2
describes errors and warnings that might appear on the VG248 either
on-screen or in the event log (see the
“Working with the Event Log” section on
page 6-22
for details on accessing the event log), which are caused by a
misconfiguration or miscommunication with the network or system settings. Use
this information to resolve these errors.
SCCP
Failed to update
real-time clock
The on-board real-time
clock in the VG248 has
failed to set the time from
Cisco CallManager.
Contact a Cisco technical
representative for assistance.
SLIC
EDSP failure
warning received
A transient fault has been
detected in the SLICs (the
hardware that drives the
analog telephony
interfaces).
If these messages persist, contact a
Cisco technical representative for
assistance.
SLIC
over-temperature
warning received
Table 6-1
Hardware Errors and Warnings Explanation (continued)
System
Error
Explanation
Action