background image

7

Using Quick Installation Brackets

A new bracket accompanies this product. See Figure 4. This bracket, with a keyhole feature, facilitates wall-mounting by 
allowing the installer to rest the bracket on a starter screw, freeing the installer’s hands. 

To rack-mount the unit, you have three positioning options. See the “Rack-Mounting the Chassis” section on page 7.

To wall-mount the unit, attach the short leg of the bracket to the chassis at the pair of holes in the center of the chassis side. 
See the “Wall-Mounting the Chassis” section on page 8.

Figure 4

Quick Installation Bracket

Rack-Mounting the Chassis

The following warning applies only when the unit is rack-mounted:

Warning

To prevent bodily injury when mounting or servicing this unit in a rack, you must take special precautions to ensure 
that the system remains stable. The following guidelines are provided to ensure your safety:

This unit should be mounted at the bottom of the rack if it is the only unit in the rack.

When mounting this unit in a partially filled rack, load the rack from the bottom to the top with the heaviest component at the 
bottom of the rack.

If the rack is provided with stabilizing devices, install the stabilizers before mounting or servicing the unit in the rack. 

Statement 1006

To rack-mount the chassis, follow this procedure:

Step 1

Choose one of the methods shown in Figure 5, Figure 6, or Figure 7, and attach the long leg of the mounting brackets 
to the chassis, as shown. 

Caution

Make sure to use the correct screws for this mounting option (see Table 1 on page 7).

Table 1

Bracket Attachment Screws for Rack-Mounting and Wall-Mounting

Rack-mounting Wall-mounting

Eight Phillips head screws (four per bracket)

Four 6-32 slotted hex screws (two per bracket) and four plastic washers

Washers are not required

Washers are required

88815

Содержание VG224 - Analog Phone Gateway

Страница 1: ...2 Related Documentation 3 Equipment Tools and Accessories 4 Product Serial Number Location 5 Installing the Chassis 6 Connecting Cables 7 Powering On the Cisco VG224 8 Performing the Initial Configuration 9 Documentation Feedback 10 Cisco Product Security Overview 11 Obtaining Documentation and Submitting a Service Request ...

Страница 2: ...the purchase price as its exclusive warranty remedy To Receive a Return Materials Authorization RMA Number Contact the company from whom you purchased the product If you purchased the product directly from Cisco contact your Cisco Sales and Service Representative Complete the information below and keep it for reference 2 Related Documentation User Documentation The latest information is always onl...

Страница 3: ...tion specific to the Cisco VG224 Voice Gateway You can find this document at the following URL http www cisco com en US products hw gatecont ps2250 products_installation_and_configuration_guides_list html Release Notes Cisco IOS release notes for the Cisco VG224 Voice Gateway provide up to date information about Cisco IOS software releases used on Cisco VG224 Voice Gateways You can find these docu...

Страница 4: ...teway Front Panel Figure 2 identifies the back panel and features of the Cisco VG224 Voice Gateway Figure 2 Identifying Back Panel Features of the Cisco VG224 Voice Gateway Figure 3 Back Panel Feature Locations Cisco VG224 RJ 21 analog voice interface FE ports 2 External compact flash 1 Chassis ground connection 5 Fast Ethernet port 0 9 On off switch 2 RJ 21 connector 6 AUX port 10 AC power input ...

Страница 5: ... Ethernet RJ 45 to RJ 45 straight through cable Analog voice RJ 21 cable Tools number 2 Phillips screwdriver medium blade screwdriver ESD preventive wrist strap 4 Product Serial Number Location The serial number label for the Cisco VG224 Voice Gateway is located on the bottom of the chassis near the compliance label The size of the serial number label is 0 25 x 1 inch It has the letters SN followe...

Страница 6: ...th Statement 1043 Warning Blank faceplates and cover panels serve three important functions they prevent exposure to hazardous voltages and currents inside the chassis they contain electromagnetic interference EMI that might disrupt other equipment and they direct the flow of cooling air through the chassis Do not operate the system unless all cards faceplates front covers and rear covers are in p...

Страница 7: ...stem remains stable The following guidelines are provided to ensure your safety This unit should be mounted at the bottom of the rack if it is the only unit in the rack When mounting this unit in a partially filled rack load the rack from the bottom to the top with the heaviest component at the bottom of the rack If the rack is provided with stabilizing devices install the stabilizers before mount...

Страница 8: ...d Step 2 Install the chassis in the rack Wall Mounting the Chassis The following warning applies only when the unit is wall mounted Warning This unit is intended to be mounted on a wall Please read the wall mounting instructions carefully before beginning installation Failure to use the correct hardware or to follow the correct procedures could result in a hazardous situation to people and damage ...

Страница 9: ...kets for Wall Mounting Step 2 Attach the second bracket to the opposite side of the chassis Step 3 Attach the router to the wall using the brackets previously attached and attachment hardware that you provide as follows You can install a starter screw in the wall and hook the bracket keyhole over the screw This holds the unit in place for easy installation of the attachment screws Attach both brac...

Страница 10: ...ductor Contact the appropriate electrical inspection authority or an electrician if you are uncertain that suitable grounding is available Statement 1024 Warning AC connected units must have a permanent ground connection in addition to the power cable ground wire NEBS compliant grounding satisfies this requirement Statement 248 1 Wall 3 Wall stud 2 Bracket 4 Keyhole for starter screw 103517 CISCO ...

Страница 11: ... the Cisco IAD chassis and the ground of a power tap and between the Cisco IAD chassis and the ground of a junction box A good ground connection should read between 0 0 and 0 5 ohms Step 2 Strip one end of the ground wire to the length required for the ground lug or terminal For the NEBS ground lug approximately 0 75 in 20 mm For user provided ring terminal as required Step 3 Crimp the ground wire...

Страница 12: ... wiring away from power cables and off premise wiring or use a grounded shield to separate the on premise wiring from the power cables and off premise wiring A power line cross is an event such as a lightning strike that causes a power surge Off premise wiring is designed to withstand power line crosses On premise wiring is protected from power line crosses by a device that provides overcurrent an...

Страница 13: ...active The ringer is activated by an incoming call Statement 1042 These cables and connections are described in Table 3 and Figure 13 Table 2 LAN Administrative Access and Power Cable Selection Port or Connection Color or Type Connected To Cable Fast Ethernet Yellow Fast Ethernet hub Straight through Fast Ethernet cable not included Console Light blue PC or ASCII terminal communication COM port RJ...

Страница 14: ...through its initialization and self test When this is finished the Cisco VG224 is ready to configure To power on the Cisco VG224 follow this procedure Step 1 Power on your terminal or PC and configure it for 9600 bps 8 data bits 1 stop bit and no parity Step 2 Move the Cisco VG224 power switch to the ON position Table 3 WAN and Voice Cable Selection Port or Interface Color or Type Connected To Cab...

Страница 15: ... time by person Step 5 Press Return to bring up the Router prompt flashfs 4 Initialization complete Router Step 6 Enter privileged EXEC mode Router enable Router Step 7 Continue with the next section Performing the Initial Configuration 8 Performing the Initial Configuration This section shows how to prepare the Cisco VG224 to perform basic communication functions through its 10 100BASE T Fast Eth...

Страница 16: ...outer config if no shutdown Activates the Fast Ethernet port Step 6 Router config if exit Returns to global configuration mode Step 7 Router config line vty 0 4 Enters line configuration mode Step 8 Router config line password password Sets a password for remote access to the Cisco VG224 Step 9 Router config line end Returns to privileged EXEC mode Step 10 Router copy system running config nvram s...

Страница 17: ... updated in real time you can access a Product Security Incident Response Team Really Simple Syndication PSIRT RSS feed from this URL http www cisco com en US products products_psirt_rss_feed html Reporting Security Problems in Cisco Products Cisco is committed to delivering secure products We test our products internally before we release them and we strive to correct all vulnerabilities quickly ...

Страница 18: ...oduct Documentation which also lists all new and revised Cisco technical documentation at http www cisco com en US docs general whatsnew whatsnew html Subscribe to the What s New in Cisco Product Documentation as a Really Simple Syndication RSS feed and set content to be delivered directly to your desktop using a reader application The RSS feeds are a free service and Cisco currently supports RSS ...

Страница 19: ...19 ...

Страница 20: ...ussia Saudi Arabia Scotland Singapore Slovakia Slovenia South Africa Spain Sweden Switzerland Taiwan Thailand Turkey Ukraine United Kingdom United States Venezuela Vietnam Zimbabwe Printed in the USA on recycled paper containing 10 postconsumer waste CCVP the Cisco logo and Welcome to the Human Network are trademarks of Cisco Systems Inc Changing the Way We Work Live Play and Learn is a service ma...

Отзывы: