C-5
Cisco UCS C220 Server Installation and Service Guide
OL-25760-01
Appendix C RAID Controller Considerations
Factory-Default Option ROM Settings
Factory-Default Option ROM Settings
Table C-4
describes the option ROM (OPROM) settings for card slots that are made at the factory for
various configurations. The version of the server and the number of CPUs affect the OPROM settings.
Note
If an option is listed as “not allowed” in
Table C-4
, that is because it is not supported in the particular
configuration described in that table row. See the footnotes below the table for more information.
For additional information about RAID controller support, see
Supported RAID Controllers and
Required Cables, page C-2
.
Table C-4
Cisco UCS C220 Factory-Default Option ROM Settings
Server Version
Number
of CPUs
Embedded
SW RAID
Enabled?
Mezz. RAID
Controller
Installed?
PCIe RAID
Controller 1
Installed?
PCIe RAID
Controller 2
Installed?
LOM
ports
Comments
C220 SFF 8 HDD/
C220 LFF 4 HDD
1
Enabled
Not allowed
1
1. You cannot use the embedded SW RAID and HW RAID (mezzanine or PCIe card) at the same time.
Not allowed
Not allowed
Always
enabled
All other OPROM
is disabled.
C220 SFF 8 HDD/
C220 LFF 4 HDD
1
Not allowed Not allowed
2
2. In single-CPU configurations, the mezzanine card slot is not supported.
Installed
:
PCIe slot 1
enabled
3
3. In single-CPU configurations, PCIe slot 2 is not available.
Not allowed
Always
enabled
All other OPROM
is disabled.
C220 SFF 8 HDD/
C220 LFF 4 HDD
2
Enabled
Not allowed
Not allowed
Not allowed
Always
enabled
All other OPROM
is disabled.
C220 SFF 8 HDD/
C220 LFF 4 HDD
2
Not allowed
Installed
:
connector
enabled
Not allowed
4
4. You cannot mix controller types in a server. A PCIe-style controller cannot be used when a mezzanine-style controller is used.
Not allowed
Always
enabled
All other OPROM
is disabled.
C220 SFF 8 HDD/
C220 LFF 4 HDD
2
Not allowed Not allowed
5
5. You cannot mix controller types in a server. A mezzanine-style controller cannot be used when a PCIe-style controller is used.
Installed
:
PCIe slot 2
enabled
Not allowed
Always
enabled
All other OPROM
is disabled.
Содержание UCS C220
Страница 12: ...xii Cisco UCS C220 Server Installation and Service Guide OL 25760 01 Preface ...
Страница 14: ...xiv Cisco UCS C220 Server Installation and Service Guide OL 25760 01 Preface ...
Страница 20: ...1 6 Cisco UCS C220 Server Installation and Service Guide OL 25760 01 Chapter 1 Overview ...
Страница 134: ...D 2 Cisco UCS C220 Server Installation and Service Guide OL 25760 01 Appendix D Installation for Cisco UCS Integration ...