3-15
Cisco UCS C220 M4 Server Installation and Service Guide
OL-32473-01
Chapter 3 Maintaining the Server
Installing or Replacing Server Components
Replacing a SAS/SATA Drive
Note
You do not have to shut down the server or drive to replace SAS/SATA hard drives or SSDs because they
are hot-swappable. To replace an NVMe PCIe SSD drive, which must be shut down before removal, see
Replacing a 2.5-Inch Form-Factor NVMe PCIe Solid State Drive, page 3-16
.
Step 1
Remove the drive that you are replacing or remove a blank drive tray from the bay:
a.
Press the release button on the face of the drive tray. See
.
b.
Grasp and open the ejector lever and then pull the drive tray out of the slot.
c.
If you are replacing an existing drive, remove the four drive-tray screws that secure the drive to the
tray and then lift the drive out of the tray.
Step 2
Install a new drive:
a.
Place a new drive in the empty drive tray and install the four drive-tray screws.
b.
With the ejector lever on the drive tray open, insert the drive tray into the empty drive bay.
c.
Push the tray into the slot until it touches the backplane, and then close the ejector lever to lock the
drive in place.
Figure 3-8
Replacing Hard Drives
1
Ejector lever
3
Drive tray securing screws (4)
2
Release button
–
353094
BAY 02
BAY 01
BAY 04
BAY 05
BAY 06
BAY 08
BAY 07
1
2
3
3
3