Multichannel STM-1 Port Adapter for the Cisco 7500 Series Router
Configuration Tasks
15
12.0(14)S
Data in current interval (137 seconds elapsed):
0 Line Code Violations, 0 Path Code Violations
0 Slip Secs, 0 Fr Loss Secs, 0 Line Err Secs, 0 Degraded Mins
0 Errored Secs, 0 Bursty Err Secs, 0 Severely Err Secs
0 Unavail Secs
[display text omitted]
Router#
show controller sonet 2/0/0 brief
SONET 2/0/0 is up.
Channelized OC-3/STM-1 SMI PA
H/W Version :0.2.3, ROM Version :1.2
FREEDM version :2, F/W Version :1.2.0
Applique type is Channelized Sonet/SDH
Clock Source is Internal, AUG mapping is AU4.
Medium info:
Type:SDH, Line Coding:NRZ, Line Type:Short SM
Regenerator Section Status:
No alarms detected.
Multiplex Section Status:
No alarms detected.
Higher Order Path Status:
Path# 1 has no defects
Lower Order Path Status:
VC-12 1/1/1/1 has no defects
VC-12 1/1/1/2 has no defects
VC-12 1/1/1/3 has no defects
VC-12 1/1/2/1 has no defects
VC-12 1/1/2/2 has no defects
VC-12 1/1/2/3 has no defects
[display text omitted]
SONET 2/0/0 E1 1/1/1/1 is up
No alarms detected.
Framing is crc4, Clock Source is internal, National bits are 0x1F.
SONET 2/0/0 E1 1/1/1/2 is up
No alarms detected.
Framing is crc4, Clock Source is internal, National bits are 0x1F.
SONET 2/0/0 E1 1/1/1/3 is up
No alarms detected.
Framing is crc4, Clock Source is internal, National bits are 0x1F.
[display text omitted]
Router#
show controller sonet 2/0/0 tabular
SONET 2/0/0 is up.
Channelized OC-3/STM-1 SMI PA
H/W Version :0.2.3, ROM Version :1.2
FREEDM version :2, F/W Version :1.2.0
Applique type is Channelized Sonet/SDH
Clock Source is Internal, AUG mapping is AU4.
Medium info:
Type:SDH, Line Coding:NRZ, Line Type:Short SM
Regenerator Section Status:
No alarms detected.
Multiplex Section Status:
No alarms detected.