1-7
Cisco Nexus 2000 Series Hardware Installation Guide
OL-19013-05
Chapter 1 Using a Fabric Extender with a Cisco Nexus 5000 Series Switch
Cisco Nexus 2248TP-E
Figure 1-7
Blank Power Supply Filler Panel for the Cisco Nexus 2200 Platform Chassis
For power supply specifications, see the
“Power Specifications” section on page B-1
. To replace a power
supply, see the
“Removing and Installing Power Supplies” section on page 3-17
. For LED descriptions,
see
Table D-1 on page D-2
.
Fan Trays
The Cisco Nexus 2248TP-E FEX has one fan tray that is hot swappable during operations. Depending
on the arrangement of hot and cold aisles in your data center, you can order front-to-back airflow to
position the front of the FEX chassis in a cold aisle or back-to-front airflow to position the back of the
FEX chassis in a cold aisle.
Table 1-2
lists the part numbers for each of the fan trays that you can use
with the Cisco Nexus 2248TP-E chassis.
Figure 1-8
shows a front-to-back airflow fan tray, and
Figure 1-9
shows a back-to-front airflow fan tray.
2
1
2
3
9290
1
Handle
2
Ejector latch
Table 1-2
Fan Trays for the Cisco Nexus 2248TP-E FEXs
Description
Part Number
Front-to-back airflow
N2K-C2248TP-FAN
Back-to-front airflow
N2K-C2248TP-FAN-B
Содержание SR2016T-NA
Страница 8: ...Contents viii Book Title 78 xxxxx xx ...
Страница 13: ...xiii Cisco Nexus 2000 Series Hardware Installation Guide OL 19013 05 Preface ...
Страница 15: ...xv Cisco Nexus 2000 Series Hardware Installation Guide OL 19013 05 Preface ...
Страница 142: ...D 6 Cisco Nexus 2000 Series Fabric Extenders Hardware Installation Guide OL 19013 05 Appendix D LEDs Port LEDs ...
Страница 160: ...Index IN 8 Cisco Nexus 2000 Series Hardware Installation Guide OL 19013 05 ...