2
Cisco SFS 7024 InfiniBand Server Switch Hardware Users Guide
OL-8794-04
Chapter
SFS 7024 Product Specifications
Mechanical/Thermal/Power Specifications
•
14U - 19" rack mount environment
•
Integrated thermal management
•
Front-to-back airflow
•
Hot plug, redundant cooling
•
Hot plug, redundant power supplies
•
90/264 VAC operation
•
50/60 Hz Frequency
•
Redundant, isolated AC inputs
•
FCC and VCCI compliant
•
U.L. Listed
Thermal Management Features
•
Eight (8) fan trays, hot plug, N+1 fans
•
Two (2) fans per tray, 60mm, 12VDC
•
Available air flow: 400 cfm @ .20 in H2O
•
Expected air velocity on the switch chip: 400 lfpm
•
Fan rotation monitor
•
I2C interface to CME
•
Thermal input from ambient air sensor and Switch chip via IBML links
Power Design Features
•
Up to twelve (12), 350 Watt power supplies
•
3.30" Width x 10.67" Depth x 1U height
•
12V bulk power
•
Status indicators
•
Four (4) independent AC input lines
Switch Characteristics
•
14U form factor
•
Full module enclosure
•
Available power (all copper): 1489 Watts max
Содержание SFS 7024