Resetting the Device
Resetting the Device
Procedure
To reset the Cisco I/O Extender for system recovery, perform the following steps:
Step 1
On the back of the device insert the end of a paper clip into the small hole (to the right of the Ethernet
connector).
Step 2
Power cycle the device by pressing and holding the Reset button for about 5-7 seconds and the Status LED
blinks orange. This action starts the recovery process.
Using the Identification Button
•
To reset the device to the network defaults, power cycle the Cisco I/O Extender (using the power
button on the front of the device) and hold the Identification button until the Data, Link, and Power
LEDs are solid blue; immediately release the button.
•
If during the boot sequence, the Status LED stays Orange, press and hold the Identification button
until the LED blinks Blue, and then release it.
Specifications
Table 1
Cisco I/O Extender Specifications
Basic Specifications
Description
Status LEDs
4
Serial Ports (Male DB9 RS232)
4
IR Outputs
8
Contacts
8
Relays 8
Network Connectivity
10/100 BaseT Ethernet
Power Supply
100–240 VAC
Amps
0.55 A
Hertz
50–60 Hz
Wattage
30W
Dimensions (H x W x D)
1.59 in. × 16.84 in. × 6.34 in.
(40.39 mm × 427.74 mm × 161.04 mm)
Weight
4.8 lb. (2.18 kg)
Power Cord
1
IR Emitter Cables
6
Rack Ears
Included