Checking the Operating
Status using the ICIM
51
Checking the Operating Status using the ICIM
To Check the Operating Status using ICIM
You can use the ICIM to check the status of all operating parameters of this
module. All status information is displayed on the ICIM LCD.
1
At the MAIN menu, press the
key to highlight the
Shelf
and
Slot
fields
.
2
Press the
key to address the
Shelf
number. Then press the
key or the
key to scroll to the number of the desired shelf.
3
Press the
key. The
Slot
field is highlighted.
4
Press the
key or the
key to scroll to the number of the
desired slot.
5
Press the
key. The
MODULE
menu appears on the ICIM LCD.
6
Press the
key.
7
Press the
key or the
key to scroll through the monitored
parameters until you find the parameter of interest.
8
Check the status of the desired parameter or select other parameters to
monitor. When finished, press the
key to return to the
MAIN
menu.
STATUS Menus
Press the
key to select the STATUS menu. Typical STATUS menus are
shown below.
q
SEL
Ì
ENTER
Ì
ENTER
STAT
p
q
MAIN
STAT
STATUS
P2HD1.215TXM
OutPwr
10
.
2 dBm
STATUS
STATUS
STATUS
Shelf
5
Slot
12
InRF
0
.
5 dB
TecCur
125
mA
ModTemp
30
.
3 degC
LasTemp
20
.
5 degC
LasRF
-
9
.
890
dB
Enable
ON
LasBias
97 mA
Shelf
5
Slot
12
Shelf
5
Slot
12
Shelf
5
Slot
12
P2HD1.215TXM
P2HD1.215TXM
P2HD1.215TXM
Содержание Prisma II HD-LRMW
Страница 2: ......
Страница 20: ......
Страница 29: ...Description 5 ...
Страница 60: ...Chapter 2 Module Installation 36 ...
Страница 64: ...Chapter 3 Operation Using the ICIM 40 ICIM2 Front Panel ICIM2 Illustration Front Panel ...
Страница 86: ......
Страница 95: ...Connecting Your Computer to the Chassis 71 Prisma II XD Chassis Top Right Corner Detail ...
Страница 110: ......
Страница 116: ......
Страница 127: ......