Chapter 12 Performance Monitoring
12.5.1 OC-48/STM16 and OC-192/STM64 Card Performance Monitoring Parameters
Figure 12-4
PM Read Points on the OC-48/STM16 and OC-192/STM64 Cards
Note
For PM locations relating to protection switch counts, see the Telcordia GR-1230-CORE document.
lists the near-end and far-end section layer PMs.
S
end vi
a
the
O&M B
us
CXC C
a
rd
OC-N C
a
rd
S
end to PM m
a
n
a
ger
vi
a
Ethernet
S
end to PM m
a
n
a
ger
vi
a
Ethernet
7
8
56
3
HW
monitor
Al
a
rm
a
gent
PM
a
gent
C
u
rrent
defect
t
ab
le
C
u
rrent
defect
t
ab
le
B1, B2,
B
3
, PJ
collection
Agent
PM
a
gent
S
witch
co
u
nt
1+1
s
witch
a
gent
Table 12-3
OC48/STM16 and OC-192/STM64 Card PMs
Section (NE)
Line (NE)
STS Path (NE)
1
,
2
1.
SONET path performance monitoring parameters increment only if IPPM is enabled. For additional information, see
the
“12.2 Intermediate-Path Performance Monitoring” section on page 12-2
. To monitor SONET path performance
monitoring parameters, log into the far-end node directly.
2.
For information about troubleshooting path protection switch counts, see For information about creating circuits with
protection switching, refer to the
Cisco ONS 15600 Reference Manual
.
Line (FE)
Optics (NE)
3
,
4
3.
The normalized physical layer performance parameters are represented as a percentage of the nominal operating value,
with 100 representing the nominal value
4.
To set the threshold values for LBC, OPT, and OPR, and to reset the OPR nominal value for future calculation, refer
to the
Cisco ONS 15600 Procedure Guide
.
STS Path (FE)
CV-S
ES-S
SES-S
SEF-S
CV-L
ES-L
SES-L
UAS-L
FC-L
PSC (1+1)
PSC (BLSR)
PSD
PSC-W
PSD-W
CV-P
ES-P
SES-P
UAS-P
FC-P
PPJC-PDET
NPJC-PDET
PPJC-PGEN
NPJC-PGEN
CV-LFE
ES-LFE
SES-LFE
UAS-LFE
FC-LFE
OPT
OPR
LBC
5
5.
As stated in Telcordia GR-253-CORE, the LBC (TCA) PM value is not appropriate for use with some optical
transmitter technologies. Such is the case for Cisco's uncooled SR optical transmitters. The default LBC TCA provides
safe operating parameter for both of Cisco's cooled and uncooled transmitters.
CV-PFE
ES-PFE
SES-PFE
UAS-PFE
FC-PFE
Содержание ONS 15600 Series
Страница 27: ...xxvii Cisco ONS 15600 Reference Manual R7 0 About this Manual ...
Страница 29: ...xxix Cisco ONS 15600 Reference Manual R7 0 About this Manual ...
Страница 52: ...1 22 Cisco ONS 15600 Reference Manual R7 0 Chapter 1 Shelf and Backplane Hardware 1 11 5 Card Replacement ...
Страница 80: ...2 28 Cisco ONS 15600 Reference Manual R7 0 Chapter 2 Card Reference 2 9 Filler Card ...
Страница 110: ...5 10 Cisco ONS 15600 Reference Manual R7 0 Chapter 5 Security 5 4 2 Shared Secrets ...
Страница 142: ...7 28 Cisco ONS 15600 Reference Manual R7 0 Chapter 7 Circuits and Tunnels 7 16 Server Trails ...
Страница 270: ...13 16 Cisco ONS 15600 Reference Manual R7 0 Chapter 13 SNMP 13 8 5 History Control RMON Group ...