Chapter 3 Connecting the Cisco ONS 15540 ESPx
Connecting the 2.5-Gbps Transponder Module
3-40
Cisco ONS 15540 ESPx Hardware Installation Guide
78-16436-01
Figure 3-27 Locking the Drawer
Step 4
Use the MTP cable installation tool to push the MTP connector on the cable into
the adapter on the 2.5-Gbps transponder module until the connector snaps into
place.
Step 5
Route the MTP cable down through the cable management tray. Pull the cable out
the left side of the tray.
Step 6
Route the cable down the left side of the chassis and into the drawer.
Step 7
Pull the cable through the vertical cable guides on the side of the cable storage
drawer.
Step 8
Route the cables through the storage drawer as directed in Steps 5 to 7 in the
“Direct Connections with Cable Storage Drawers” section on page 3-16
.
Step 9
Close the cable storage drawer once the cables are routed out of the right side and
you unlock the drawer.
Step 10
Open the cross connect drawer appropriate for your system configuration. See
Step 1 to Step 3 above for drawer opening details.
Step 11
Flip the latches on the cross connect panel up and use them to pull the panel up.
(See
79727
Содержание ONS 15540 ESPx
Страница 6: ......
Страница 12: ...Contents x Cisco ONS 15540 ESPx Hardware Installation Guide 78 16436 01 ...
Страница 214: ...Index IN 8 Cisco ONS 15540 ESPx Hardware Installation Guide 78 16436 01 ...