C H A P T E R

3

Installing the Chassis

Safety, on page 11

Installation Options with Rack-Mount Kits, on page 12

Airflow Considerations, on page 12

Installation Guidelines, on page 12

Unpacking and Inspecting the Switch, on page 14

Installing the Switch Using the NXK-ACC-KIT-1RU Rack-Mount Kit, on page 14

Grounding the Chassis, on page 18

Starting the Switch, on page 19

Safety

Before you install, operate, or service the switch, see the

Regulatory, Compliance, and Safety Information for

the Cisco Nexus 3000 and 9000 Series

for important Safety Information.

Statement 1071—

Warning Definition

IMPORTANT SAFETY INSTRUCTIONS

This warning symbol means danger. You are in a situation that could cause bodily injury. Before you work
on any equipment, be aware of the hazards involved with electrical circuitry and be familiar with standard
practices for preventing accidents. Use the statement number provided at the end of each warning to locate
its translation in the translated safety warnings that accompanied this device.

SAVE THESE INSTRUCTIONS

Warning

Cisco Nexus C9316D-GX ACI-Mode Switch Hardware Installation Guide

11

Содержание Nexus C9316D-GX

Страница 1: ...ardwareInstallationGuide First Published 2017 10 31 Last Modified 2019 09 30 Americas Headquarters Cisco Systems Inc 170 West Tasman Drive San Jose CA 95134 1706 USA http www cisco com Tel 408 526 4000 800 553 NETS 6387 Fax 408 527 0883 ...

Страница 2: ... 2017 Cisco Systems Inc All rights reserved ...

Страница 3: ...s 5 Altitude Requirements 5 Dust and Particulate Requirements 6 Minimizing Electromagnetic and Radio Frequency Interference 6 Shock and Vibration Requirements 7 Grounding Requirements 7 Planning for Power Requirements 7 Airflow Requirements 9 Rack and Cabinet Requirements 9 Clearance Requirements 10 Installing the Chassis 11 C H A P T E R 3 Safety 11 Installation Options with Rack Mount Kits 12 Ai...

Страница 4: ... Replacing an AC Power Supply 27 Rack Specifications 29 A P P E N D I X A Overview of Racks 29 General Requirements for Cabinets and Racks 29 Requirements Specific to Standard Open Racks 30 Requirements Specific to Perforated Cabinets 30 Cable Management Guidelines 31 System Specifications 33 A P P E N D I X B Environmental Specifications 33 Switch Dimensions 33 Switch and Module Weights and Quant...

Страница 5: ...ance Specifications 36 LEDs 39 A P P E N D I X C Switch Chassis LEDs 39 Fan Module LEDs 40 Power Supply LEDs 40 Additional Kits 43 A P P E N D I X D Rack Mount Kit NXK ACC KIT 1RU 43 Cisco Nexus C9316D GX ACI Mode Switch Hardware Installation Guide v Contents ...

Страница 6: ...Cisco Nexus C9316D GX ACI Mode Switch Hardware Installation Guide vi Contents ...

Страница 7: ...ich the user supplies the values Italic Square brackets enclose an optional element keyword or argument x Square brackets enclosing keywords or arguments separated by a vertical bar indicate an optional choice x y Braces enclosing keywords or arguments separated by a vertical bar indicate a required choice x y Nested set of square brackets or braces indicate optional or required choices within opt...

Страница 8: ... appreciate your feedback Communications Services and Additional Information To receive timely relevant information from Cisco sign up at Cisco Profile Manager To get the business impact you re looking for with the technologies that matter visit Cisco Services To submit a service request visit Cisco Support To discover and browse secure validated enterprise class apps products solutions and servic...

Страница 9: ...udes the following user replaceable components Fan modules six with the following airflow choices Port side exhaust airflow with blue coloring NXA FAN 35CFM PE Port side intake airflow with red coloring NXA FAN 35CFM PI Table 1 Fan Speeds for This Switch Port Side Exhaust Fan Speed Port Side Intake Fan Speed 80 60 Typical Minimum 100 100 Maximum Note Power supply modules two One for operations and...

Страница 10: ...e airflow direction during operations Note In the event that only one power supply is operating in an active system and a second power supply is inserted the system fan will slow down to 50 of Max speed for 12 seconds It can take up to 10 seconds for the second power supply to become active Please do not remove the first power supply during this time frame in order to avoid system shutdown Note Th...

Страница 11: ...ing functions 6 Console port RS232 port 3 USB support is limited to USB 2 0 devices that use less than 2 5 W less than 0 5 A inclusive of surge current There is no support for devices such as external hard drives that instantaneously draw more than 0 5 A Note Depending on whether you plan to position the ports in a hot or cold aisle you can order the fan and power supply modules with port side int...

Страница 12: ...e cold aisle If the switch has port side exhaust airflow blue coloring for fan modules you must locate the ports in the hot aisle If you locate the air intake in a hot aisle the switch can overheat and shut down Caution Cisco Nexus C9316D GX ACI Mode Switch Hardware Installation Guide 4 Overview Overview ...

Страница 13: ... of 32 to 104 degrees Fahrenheit 0 to 40 degrees Celsius If the switch is not operating the temperature must be between 40 to 158 degrees Fahrenheit 40 to 70 degrees Celsius Humidity Requirements Buildings in which the climate is controlled by air conditioning in the warmer months and by heat during the colder months usually maintain an acceptable level of humidity for the switch equipment However...

Страница 14: ...other devices through the power cable and power source or through the air as transmitted radio waves The Federal Communications Commission FCC publishes specific regulations to limit the amount of EMI and RFI that are emitted by computing equipment Each switch meets these FCC regulations To reduce the possibility of EMI and RFI follow these guidelines Cover all open expansion slots with a blank fi...

Страница 15: ...natively you can ground the chassis by using a customer supplied grounding cable that meets your local and national installation requirements For U S installations we recommend 6 AWG wire Connect your grounding cable to the chassis with a grounding lug provided in the switch accessory kit and to the facility ground You automatically ground AC power supplies when you connect them to AC power source...

Страница 16: ... product relies on the building s installation for short circuit overcurrent protection Ensure that the protective devices are rated not greater than 20A North America 16A Europe and 13A UK Warning For DC input application please refer to the following statement Note Statement 1005 Circuit Breaker This product relies on the building s installation for short circuit overcurrent protection Ensure th...

Страница 17: ...the same direction of airflow even if their coloring is different If you must change the airflow direction for the switch you must shutdown the switch before changing the modules Note Rack and Cabinet Requirements You can install the following types of racks or cabinets for your switch Standard perforated cabinets Solid walled cabinets with a roof fan tray bottom to top cooling Standard open four ...

Страница 18: ...flow and maintain the switch For the clearances required for an installation of this chassis in a four post rack see the following figure Depth of the chassis 5 Chassis 1 Maximum extension of the bottom support rails 6 Vertical rack mount posts and rails 2 Depth of the front clearance area equal to the depth of the chassis 7 Chassis width 3 Width of the front clearance area equal to the width of t...

Страница 19: ...d Safety Information for the Cisco Nexus 3000 and 9000 Series for important Safety Information Statement 1071 Warning Definition IMPORTANT SAFETY INSTRUCTIONS This warning symbol means danger You are in a situation that could cause bodily injury Before you work on any equipment be aware of the hazards involved with electrical circuitry and be familiar with standard practices for preventing acciden...

Страница 20: ...en installing the NXK ACC KIT 1RU rack mount kit the distance between the outside face of the front mounting rail and the outside face of the back mounting rail should be 25 37 to 35 inches 64 43 to 88 9 cm to allow for rear bracket installation Rack mount kit N3K C3064 ACC KIT which you can order from Cisco When installing the N3K C3064 ACC KIT rack mount kit the distance between the outside face...

Страница 21: ...pically require at least a 15 A or 20 A AC circuit 100 to 240 VAC and a frequency of 50 to 60 Hz To prevent loss of input power ensure the total maximum loads on the circuits supplying power to the switch are within the current ratings for the wiring and breakers Caution For AC input application please refer to the statement below Note Statement 1005 Circuit Breaker This product relies on the buil...

Страница 22: ...ollowing Accessory Kit Step 2 Check for damage and report any discrepancies or damage to your customer service representative Have the following information ready Invoice number of shipper see packing slip Model and serial number of the damaged unit Description of damage Effect of damage on the installation Installing the Switch Using the NXK ACC KIT 1RU Rack Mount Kit To install the switch you mu...

Страница 23: ...aust modules fan modules with blue coloring position the switch so that its fan and power supply modules will be in the cold aisle b Position the front rack mount bracket and the rear rack mount bracket so that its screw holes are aligned to the screw holes on the side of the chassis You can align the holes in the rack mount bracket to the holes on the side of the chassis see the two ways to mount...

Страница 24: ... the rack or cabinet two will be used for the front mount brackets attached to the easiest accessed end of the chassis and the other two posts will have the slider rails b Position a slider rail at the desired level on the back side of the rack and use 12 24 screws or 10 32 screws depending on the rack thread type to attach the rails to the rack see the following figure Tighten 12 24 screws to 30 ...

Страница 25: ...g on the rack type in each of the two front rack mount brackets using a total of six screws and into the cage nuts or threaded holes in the vertical rack mounting rails see the following figure d Tighten the 10 32 screws to 20 in lb 2 26 N m or tighten the 12 24 screws to 30 in lb 3 39 N m Step 5 If you attached a grounding wire to the chassis grounding pad connect the other end of the wire to the...

Страница 26: ...r Replacing the Unit To reduce risk of electric shock when installing or replacing the unit the ground connection must always be made first and disconnected last Warning Before you begin Before you can ground the chassis you must have a connection to the earth ground for the data center building Step 1 Use a wire stripping tool to remove approximately 0 75 inch 19 mm of the covering from the end o...

Страница 27: ...esignated power cables for the power supplies that you are connecting to the dedicated power sources Depending on the outlet receptacle on your AC power distribution unit you might need an optional jumper power cord to connect the switch to your outlet receptacle Note The switch is not connected to the network this includes any management or interface connections The fan and power supply modules a...

Страница 28: ...source are connected to a connector block c Insert the connector block into the receptacle on the power supply Make sure that the connector block clicks when fully inserted in the receptacle and does not pull out d If there is a safety cover for the terminals place and secure it over the terminals to avoid an electrical shock hazard e Turn on the power at the circuit breaker for the DC power sourc...

Страница 29: ... are connections to hosts and servers in the network Each of these connection types is explained in one of the sections that follow When running cables in overhead or subfloor cable trays we strongly recommend that you locate power cables and other potential noise sources as far away as practical from network cabling that terminates on Cisco equipment In situations where long parallel cable runs c...

Страница 30: ...ack which is connected to a power source and grounded The necessary cabling for the console management and network connections must be available An RJ 45 rollover cable provided in the switch accessory kit Network cabling is routed to the location of the installed switch Step 1 Configure the console device to match the following default port characteristics 9600 baud 8 data bits 1 stop bit No pari...

Страница 31: ...s to the same AC circuit If you are using the input source n n power mode connect half of the power supplies to one AC circuit And connect the other half of the power supplies to another AC circuit The Input and Output LEDs on each power supply light up green when the power supply units are sending power to the switch and the software asks you to specify a password to use with the switch Step 2 En...

Страница 32: ... no not to edit the configuration The software asks if you need to save the configuration Step 8 Enter yes to save the configuration What to do next You can now set up the management interface for each supervisor module on the switch Setting Up the Management Interface The RJ 45 and or SFP management ports provide out of band management which enables you to use the command line interface CLI to ma...

Страница 33: ...0G adapter in the QSFP port and then install the SFP or SFP transceiver The switch automatically sets the port speed to the speed of the installed transceiver Note If the transceivers that you are using can be separated from their optical cables install the transceivers without their cables before inserting the cables into the transceivers This helps to prolong the life of both the transceiver and...

Страница 34: ...Cisco Nexus C9316D GX ACI Mode Switch Hardware Installation Guide 26 Connecting the Switch to the Network Connecting Interface Ports to Other Devices ...

Страница 35: ...ng of the fan modules Replacing an AC Power Supply You can replace an AC power supply during operations so long as the other power supply provides to the switch Before you begin You can determine the airflow direction by looking at the coloring of the latch on each power supply AC power supplies with burgundy latches have port side intake airflow direction and power supplies with blue latches have...

Страница 36: ...pen power supply slot before carefully sliding the power supply all the way into the slot until it clicks into place If the power supply does not fit into the open slot turn the module over before sliding it carefully into the open slot Note b Test the installation by trying to pull the power supply out of the slot without using the release latch If the power supply does not move out of place it i...

Страница 37: ...racks If you are selecting an enclosed cabinet we recommend one of the thermally validated types either standard perforated or solid walled with a fan tray Note We do not recommend that you use racks that have obstructions such as power strips because the obstructions could impair access to field replaceable units FRUs Note General Requirements for Cabinets and Racks The cabinet or rack must also ...

Страница 38: ...nstallation For the specific rack dimension information for each possible rack mount see Installation Options with Rack Mount Kits on page 12 Requirements Specific to Standard Open Racks If you are mounting the chassis in an open rack no side panels or doors ensure that the rack meets the following requirements The minimum vertical rack space per chassis must be The distance between the chassis ai...

Страница 39: ...ant to allow additional space in the rack above and below the chassis to make it easier to route all of the fiber optic or copper cables through the rack Cisco Nexus C9316D GX ACI Mode Switch Hardware Installation Guide 31 Rack Specifications Cable Management Guidelines ...

Страница 40: ...Cisco Nexus C9316D GX ACI Mode Switch Hardware Installation Guide 32 Rack Specifications Cable Management Guidelines ...

Страница 41: ... Standards Compliance Specifications on page 36 Environmental Specifications Switch Dimensions Height Depth Width Switch 1 72 inches 4 4 cm 1 RU 25 5 inches 64 7 cm 17 3 inches 43 9 cm Cisco Nexus C9316D GX Switch and Module Weights and Quantities Quantity Weight per Unit Component 1 28 8 lb 13 kg Cisco Nexus 9316D GX Chassis N9K C9316D GX 3 0 6 lb 0 3 kg 0 6 lb 0 3 kg Fan Module Port side exhaust...

Страница 42: ...ation information see https www cisco com c en us support interfaces modules transceiver modules products device support tables list html Switch Power Input Requirements The following table lists the typical amount of power that the switch consumes It also lists the maximum amount of power that you must provision for the switch and power supply for peak conditions Some power supplies have UL liste...

Страница 43: ... at 100 VAC Maximum input volt amperes 1100 W Maximum output power per power supply 33 A sub cycle duration Maximum inrush current 12 ms at 1100 W Maximum hold up time 12 VDC Power supply output voltage 12 VDC Power supply standby voltage Climate Savers Platinum Efficiency 80Plus Platinum certified Efficiency rating RSP1 Form factor 1100 W HVAC HVDC Power Supply Specifications These specifications...

Страница 44: ...ge 54VDC Range 40 to 72 VDC DC input voltage range 32 A at 40 VDC Maximum DC input current 1100 W Maximum output power per power supply 90 A cold turn on Maximum inrush current 4 ms at 100 load Maximum hold up time 12 V 90A Power supply output voltage 3 3 V 3A Power supply standby voltage 94 at 50 load Efficiency rating 48VDC Power Cable Specifications The following sections specify the power cabl...

Страница 45: ...ZS 60950 1 GB4943 Safety 47CFR Part 15 CFR 47 Class A AS NZS CISPR22 Class A CISPR22 Class A EN55022 Class A ICES003 Class A VCCI Class A EN61000 3 2 EN61000 3 3 KN22 Class A CNS13438 Class A EMC Emissions EN55024 CISPR24 EN300386 KN 61000 4 series EMC Immunity The product is RoH 6 compliant with exceptions for leaded ball grid array BGA balls and lead press fit connectors RoHS Cisco Nexus C9316D ...

Страница 46: ...Cisco Nexus C9316D GX ACI Mode Switch Hardware Installation Guide 38 System Specifications System Specifications ...

Страница 47: ... activated this LED to identify this switch in the chassis Flashing blue BCN This switch is not being identified Off The switch is operational Green STS The switch is booting up Flashing amber Temperature exceeds the minor alarm threshold Amber Temperature exceeds the major alarm threshold Red The switch is not receiving power Off Fans and power supply modules are operational Green ENV At least on...

Страница 48: ...n module is not receiving power Off Power Supply LEDs The power supply LEDs are located on the left front portion of the power supply Combinations of states that are indicated by the Okay PS_OK and Fault AC_OK LEDs indicate the status for the module as shown in the following table Status AC_OK LED PS_OK LED Power supply is on and outputting power to the switch Off Green Power supply is connected t...

Страница 49: ...ior occurs if the fan rotor is stopped during normal switch operation Note Amber Green AC cord that is removed while in redundant mode while other PSU is running Amber Off Cisco Nexus C9316D GX ACI Mode Switch Hardware Installation Guide 41 LEDs LEDs ...

Страница 50: ...Cisco Nexus C9316D GX ACI Mode Switch Hardware Installation Guide 42 LEDs LEDs ...

Страница 51: ...brackets 2 Slider rails 2 M4 Phillips pan head screws 6 1 Ground lug kit Two hole lug 1 M4 x 8 mm Phillips pan head screws 2 1 EAC Compliance document Not applicable 1 Hazardous substances list for customers in China Not applicable The following table lists and illustrates the console cable CAB CONSOLE RJ45 that can be ordered Quantity Description Illustration 1 Console cable with DB 9F and RJ 45F...

Страница 52: ...Cisco Nexus C9316D GX ACI Mode Switch Hardware Installation Guide 44 Additional Kits Additional Kits ...

Отзывы: