Cisco Nexus 4001I and 4005I Switch Module for IBM BladeCenter Getting Started Guide
OL-19952-02
Configuring the Switch
Figure 2
AMM I/O Module Admin/Power/Restart Window
Step 5
From the External ports drop-down list, choose
Enabled
to enable external ports on the switch module.
Step 6
Click
Save
to save your settings.
Step 7
In the left pane, expand I/O Module Tasks, and click
Configuration
.
Step 8
In the I/O Module Power/Restart area, check the check box for the bay that corresponds to the location
of the I/O module (switch module) that you are configuring.
Note
The switch module can only be installed in Bays 7 through 10.
The applicable bay number appears in the pane, followed by other related I/O-module information,
including the IP address. The I/O-module information is divided into two areas: Current IP
Configuration and New Static IP Configuration (see
Figure 3
).