1 x PWR-RPS2300
2 x C3K-PWR-1150WAC (2300W)
6 x CAB-RPS2300-E=
Example 3:
I have 3 x MS220-48 and 3 x MS220-48LP connected to RPS2300. I also intend to use the full PoE budget
on each of the PoE switches but I do not need to back it up in case of a failure.
3 x 51 = 153W
3 x 135 = 405W
153W + 405W = 558W total power draw
Recommended hardware:
1 x PWR-RPS2300
1 x C3K-PWR-750WAC (750W) OR 2 x C3K-PWR-750WAC (750W) for redundancy
6 x CAB-RPS2300-E=
Mounting hardware
The mounting hardware includes a rack mount kit for standard 1U racks. When installing the device, make sure that
there is sufficient space between the rear of the rack and other obstacles to ensure adequate airflow.
Only the RPS2300 chassis (PWR-RPS2300) and accessories are supported. For more information, see
the
RPS2300 datasheet