failure.
controller
assembly.
1618 - PCI slots powered down.
Check PCI hot plug
enabler connectors.
None
PCI hot plug
enabler is
missing or
failed.
Check and
replace missing
or failed
controller
assembly.
1620 - Locked SCSI Bus
Detected. Verify SCSI bus
cabling. System halted.
None
SCSI bus
failure.
1. Run
diagnostics.
2. Replace
failed assembly
as indicated.
1621 - Current SCSI Jumper
Board Not Installed.
None
Improper
SCSI bus
cabling.
Check
documentation
for proper
SCSI bus
cabling.
1622 - Internal SCSI Jumper
Board Not Installed.
None
The system
has detected
that the array
enabler board
is not
installed.
Install the array
enabler board.
1703 - SCSI cable error
detected. Internal SCSI
cable not attached
to system board
connector. System halted.
None
Incorrect
cabling.
Ensure that the
integrated
SCSI controller
has SCSI
termination
attached.
1720 - Slot x Drive
Array - SMART Drive
Detects Imminent
Failure SCSI:
Port y: SCSI ID x
None
Indicated
drive has
reported a
SMART
predictive-
failure
condition and
can fail at
some time in
the future.
1. If the drive
is part of a
nonfault-
tolerant
configuration,
back up all data
before you
replace the
drive and
restore all data
afterward. If
the drive is part
of a fault-
tolerant
configuration
do not replace
the drive unless
Page 9 of 13
Cisco - Cisco MCS-78XX Boot Error Codes
10/2/2008
http://kbase.cisco.com/paws/servlet/ViewFile/12138/mcs_boot.xml?convertPaths=1