215 - Processor Power Module  
has lost Redundancy  
in Socket x 

None 

(Processor 
Power 
Module) 
(DC-DC 
Converter) 
has lost 
redundancy. 

Run 
Diagnostics. 
Replace failed 
assembly as 
indicated. 

216 - Voltage Regulator Module  
for Processor x  
no longer redundant. 

None 

Redundancy 
failed in 
PPM. 

Replace the 
PPM to restore 
redundancy. 

216 - Processor PPM has  
lost Redundancy Module X 

None 

Indicated 
PPM (DC-
DC 
Converter) 
has lost 
redundancy. 

Replace failed 
assembly as 
indicated. 

218 - Cache Accelerators  
Not Installed.  
System Halted. 

None 

Cache 
Accelerators 
not installed 
or improperly 
installed. 

Check the 
Cache 
Accelerator 
installation. 

219 - Tag Update Rules  
SRAM Failure.  
System Halted 

None 

Catastrophic 
chipset 
failure. 

Call the 
Compaq 
service 
provider. 

219 - Snoop Rules SRAM Failure. 
System Halted 

None 

Catastrophic 
chipset 
failure. 

Call Compaq 
service 
provider. 

220 - Cache Accelerator  
Slot x initialization Failed.  
System Halted. 

None 

Cache 
Accelerator 
in slot x 
improperly 
installed or 
bad.  

Check Cache 
Accelerator 
installation and 
if properly 
installed, 
replace. 

221 - Power Fault On  
Processor Bus X 

None 

A PPM on 
indicated bus 
is in a failed 
state.  

Run 
Diagnostics. 
Replace failed 
assembly as 
indicated. 

301 - Keyboard Error 

None 

Keyboard 
failure. 

Turn off the 
computer, then 
reconnect the 
keyboard. 

301- Keyboard Error or Test  
Fixture Installed 

None 

Keyboard 
failure. 

Replace the 
keyboard. 

Page 6 of 13

Cisco - Cisco MCS-78XX Boot Error Codes

10/2/2008

http://kbase.cisco.com/paws/servlet/ViewFile/12138/mcs_boot.xml?convertPaths=1

Содержание MCS-78 Series

Страница 1: ... and hardware versions z Cisco MCS 78xx series servers z Cisco MCS 78xx Operating System OS V2000 x or later The information in this document was created from the devices in a specific lab environment All of the devices used in this document started with a cleared default configuration If your network is live make sure that you understand the potential impact of any command Conventions TAC Notice ...

Страница 2: ...error in the system an error condition is indicated by an audible or visual message If an error code displays on the screen during POST or after you reset the system use the instructions in the POST Error Messages table found in this document Note Many of the actions listed require you to run Diagnostics or the Compaq System Configuration Utility These utilities can be downloaded from the Compaq H...

Страница 3: ...n is corrected If the error code reappears perform the next step then run the Diagnostics program again Follow this procedure until Diagnostics no longer detects an error condition Error Code Audible Beeps Probable Source of Problem Recommended Action A Critical Error occurred prior to this power up None A catastrophic system error which cause the server to crash has been logged Run Diagnostics Re...

Страница 4: ...time or date in configuration memory Run the System Configuration Utility and correct 172 Configuration Nonvolatile Memory Invalid None Nonvolatile configuration corrupt or jumper installed Run the System Configuration Utility and correct 177 Configuration Not Complete None Incomplete system configuration Run the System Configuration Utility and correct 178 Processor Configuration Invalid None Pro...

Страница 5: ...ory modules installed and replace if slower than 60 ns 209 Memory Detection Failure Check Memory Installation 1 long 1 short Unable to size memory Check DIMM Installation and if error persists call the Compaq service provider 211 Cache Switch Set Incorrectly None Switch not set properly during installation or upgrade Verify switch settings 212 System Processor Failed Mapped out 1 short Processor i...

Страница 6: ...System Halted None Catastrophic chipset failure Call the Compaq service provider 219 Snoop Rules SRAM Failure System Halted None Catastrophic chipset failure Call Compaq service provider 220 Cache Accelerator Slot x initialization Failed System Halted None Cache Accelerator in slot x improperly installed or bad Check Cache Accelerator installation and if properly installed replace 221 Power Fault ...

Страница 7: ...rt indicated 40X Parallel Port X Address Assignment Conflict 2 short Both external and internal ports are assigned to parallel port X Run the System Configuration Utility and correct 601 Diskette Controller Error None Diskette controller circuitry failure 1 Make sure the diskette drive cables are attached 2 Replace the diskette drive and or cable 3 Replace the system board 605 Diskette Drive Type ...

Страница 8: ...d Replace the failed fan 1612 Primary power supply failure 2 short Primary power supply has failed Replace power supply as soon as possible 1613 Low System Battery on power None Real time clock system battery is running low Run diagnostics Replace failed assembly as indicated 1615 Power Supply Failure Power Supply Unplugged or Power Supply Fan Failure in Bay X None A power supply has failed Replac...

Страница 9: ...d Install the array enabler board 1703 SCSI cable error detected Internal SCSI cable not attached to system board connector System halted None Incorrect cabling Ensure that the integrated SCSI controller has SCSI termination attached 1720 Slot x Drive Array SMART Drive Detects Imminent Failure SCSI Port y SCSI ID x None Indicated drive has reported a SMART predictive failure condition and can fail...

Страница 10: ...Slot x Drive Array Physical Drive Position Change s Detected Logical drive configuration has automatically been updated None Logical drive configuration has been updated automatically following physical drive position changes Press F1 to resume 1726 Slot x Drive Array Array Accelerator Memory Size Change Detected None Indicates array accelerator configuration has been updated automatically due to ...

Страница 11: ...l Auto Reliability Monitoring has completed automatic parity consistency initialization None Normal operation This message is normal following the initial configuration of RAID 4 or RAID 5 logical drives This POST message goes away and performance of the controller improves after the parity data is initialized by ARM an automatic process that runs in the background on the controller 1730 Fixed Dis...

Страница 12: ...ct 1 2008 Securing Publicly Located VoIP Phones Sep 30 2008 MCU EMP start setup over telnet Sep 30 2008 Voice Video IP Telephony When to use a tech prefix and when not to Oct 2 2008 CFWdAll Does it work by line or all lines Oct 2 2008 unable to receive voice calls Oct 2 2008 Detailed Reports on Numbers Dialed on CCM Help Oct 2 2008 Translation pattern issue Oct 2 2008 Voice Video IP Phone Services...

Страница 13: ...l character escape Oct 2 2008 Get personal address book and speed dial information from call manager Sep 30 2008 CCM 4 1 3 DN Parameter on Service Sep 29 2008 Outlook VB Code to Dial CISCO IP PHONE 7960 Series Sep 29 2008 Voice Video General Maintaining the Directory in Cisco CallManager Attendant console Oct 2 2008 External Calls Transfered to External Calls Fail CCM 6 1 and h 323 Oct 2 2008 3845...

Отзывы: