Bandwidth Management
4-Port SSL/IPSec VPN Router
Appendx C
Creation of New Bandwidth Management
Rules
Create four new rules: Vonage VoIP (Upstream), Vonage
VoIP (Downstream), Vonage 2 (Upstream), and Vonage 2
(Downstream).
On the
Bandwidth Management
screen, select
Vonage
VoIP
from the
Service
drop-down menu.
Enter the IP address or range you need to control. To
include all internal IP addresses, keep the default,
0
.
From the
Direction
drop-down menu, select
Upstream
for outbound traffic.
In the
Min. Rate
field, enter the minimum rate for the
guaranteed bandwidth. For example, you can set a
minimum rate of 40 kbit/sec.
In the
Max. Rate
field, enter the maximum rate for
the maximum bandwidth. For example, you can set a
maximum rate of 80 kbit/sec.
Select
Enable
to enable this rule.
After you have set up the rule, click
Add to lst
.
Create Vonage VoIP Rule
Set up a second rule for Vonage VoIP, this time for the
Downstream direction.
Select
Vonage VoIP
from the
Service
drop-down
menu.
Enter the IP address or range you need to control. To
include all internal IP addresses, keep the default,
0
.
From the
Direction
drop-down menu, select
Downstream
for inbound traffic.
In the
Min. Rate
field, enter the minimum rate for the
guaranteed bandwidth. For example, you can set a
minimum rate of 40 kbit/sec.
In the
Max. Rate
field, enter the maximum rate for
the maximum bandwidth. For example, you can set a
maximum rate of 80 kbit/sec.
Select
Enable
to enable this rule.
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
After you have set up the rule, click
Add to lst
.
Set up a rule for Vonage 2. Select
Vonage
from the
Service
drop-down menu.
Enter the IP address or range you need to control. To
include all internal IP addresses, keep the default,
0
.
From the
Direction
drop-down menu, select
Upstream
for outbound traffic.
In the
Min. Rate
field, enter the minimum rate for the
guaranteed bandwidth. For example, you can set a
minimum rate of 40 kbit/sec.
In the
Max. Rate
field, enter the maximum rate for
the maximum bandwidth. For example, you can set a
maximum rate of 80 kbit/sec.
Select
Enable
to enable this rule.
After you have set up the rule, click
Add to lst
.
Set up a second rule for Vonage 2 (Downstream). Select
Vonage
from the
Service
drop-down menu.
Enter the IP address or range you need to control. To
include all internal IP addresses, keep the default,
0
.
From the
Direction
drop-down menu, select
Downstream
for inbound traffic.
In the
Min. Rate
field, enter the minimum rate for the
guaranteed bandwidth. For example, you can set a
minimum rate of 40 kbit/sec.
In the
Max. Rate
field, enter the maximum rate for
the maximum bandwidth. For example, you can set a
maximum rate of 80 kbit/sec.
Select
Enable
to enable this rule.
After you have set up the rule, click
Add to lst
.
Create Vonage 2 Rule
Click
Save Settngs
.
14.
15.
16.
17.
18.
19.
20.
21.
22.
23.
24.
25.
26.
27.
28.
29.