Rack-Mount the Chassis
Step 1
Place the chassis with the top facing down on a large, stable work area. .
Step 2
Invert the sliding shelf and position it on the chassis. You can mount the chassis with the front or rear panel facing front.
Figure 25: Install the Rack-Mount Shelf on the Chassis
Step 3
Adjust the position of the chassis and the shelf until the three mounting holes in the dimples in the bottom of the shelf
are aligned with the mounting holes in the bottom of the chassis.
Step 4
Tighten the captive screws to lock the chassis into place on the rack-mount shelf.
Step 5
Carefully turn the rack-mount shelf right-side up.
Step 6
Install the power supply and bracket behind the chassis. Tighten the three screws on the bracket to secure it to the rack
shelf. You can tighten the thumb screw on the top of the bracket to secure the power supply. The bracket flexes when
the power supply is properly secured.
If you are using a torque screw driver or drill do not use more than 4 in-lbs.
Caution
Cisco Firepower 1010 Hardware Installation Guide
29
Mount the Chassis
Rack-Mount the Chassis