National Restrictions within the European Union
Within the European Union as well as within the majority of the other European Countries, the 2.4 and 5 GHz bands are available
for use by wireless LANs.
The following table provides an overview of the regulatory requirements that are generally applicable for 2.4 and 5 GHz bands.
The requirements for any country might evolve. We recommend that you check with your local authorities for the current status of
regulations for 2.4 and 5 GHz wireless LANs within your country.
Table 3: Overview of Regulatory Requirements for Wireless LANs
Indoor and Outdoor
Indoor only
Maximum Power Level
Effective Isotropic Radiated
Power (EIRP) mW
Frequency Band (MHz)
x
—
100
2400-2483.5
—
x
200
5150-5350
x
—
1000
5470-5725
Tools and Hardware Required
These tools and hardware are required for access point installation:
•
Crimping tool (such as Thomas & Bett part number WT2000, ERG-2001, or equivalent)
•
6-gauge copper ground wire
•
Wire-stripping tools for stripping 6-gauge wire
•
Number 2 Phillips screwdriver
•
1/2" (13 mm) socket for port plug
•
5/8" (16 mm) socket for protective vent
•
5/32" (4 mm) hex key for mounting screws
•
Torque wrench (both inch-lbs and ft-lbs)
Installation Guidelines
Because the access point is a radio device, it is susceptible to common causes of interference that can reduce throughput and range.
Follow these guidelines to ensure the best possible performance:
•
For information on planning and initially configuring your Cisco Mesh network, refer to the
Cisco Wireless Mesh Access Points,
Design and Deployment Guide
.
•
Review the FCC Guidelines for Installation and Operation of Outdoor Wireless LAN Devices (U-NII devices) Operating in the
5470-5725 MHz Band Data Sheet at:
http://www.cisco.com/c/en/us/products/collateral/routers/3200-series-rugged-integrated-services-routers-isr/data_sheet_c78-647116.html