Software Configuration of ATM ISE Line Cards for Cisco 12000 Series Routers
How to Configure AToM VCs on the 4-Port ATM ISE Line Card
56
Cisco IOS Release 12.0(27)S
Step 5
queue-limit
number-of-cells
cells
Example:
Router(config-pmap-c)# queue-limit 300 cells
Specifies or modifies the maximum number of cells the
queue can hold for a class policy configured in a policy
map.
Step 6
exit
Example:
Router(config-pmap-c)# exit
Exits class mode.
Step 7
exit
Example:
Router(config-pmap)# exit
Exits policy-map mode.
Step 8
interface atm
slot/port
Example:
Router(config)# interface atm1/0
Specifies an ATM interface or subinterface to configure.
Step 9
atm clock internal
Example:
Router(config)# atm clock internal
Causes the ATM interface to generate the transmit clock
internally.
Step 10
atm mcpt-timers
[
timer1-timeout timer2-timeout
timer3-timeout
]
Example:
Router(config-if)# atm mcpt-timers 100 1000
5000
Sets up the cell-packing timers, which specify how long the
PE router can wait for cells to be packed into an MPLS
packet.
You can set up to three timers. For each timer, you specify
the maximum cell packing timeout (MCPT). This value
gives the cell packing function a limited amount of time to
complete. If the timer expires before the maximum number
of cells are packed into an AToM packet, the packet is sent
anyway. The range of values is from 2 to 4095.
Step 11
pvc
[
name
]
vpi/vci
l2transport
Example:
Router(config-if)# pvc 21/21 l2transport
Specifies a PVC with the specified VPI and virtual circuit
identifier (VCI). The
l2transport
keyword indicates that
the PVC is a switched PVC and not a terminated PVC.
Step 12
encapsulation aal0
Example:
Router(config-atm-l2trans-pvc)# encapsulation
aal0
For ATM Cell Relay, this command specifies raw cell
encapsulation for the interface. Make sure you specify the
same encapsulation type on the PE and CE routers.
Step 13
cell-packing
cells
mcpt-timer
timer
Example:
Router(config-atm-l2trans-pvc)# cell-packing 10
mcpt-timer 1
Enables cell packing and specifies the cell packing
parameters.
The
cells
value represents the maximum number of cells to
be packed into an MPLS packet. The range is from 2 to 28.
The
timer
value
allows you to specify which timer to use.
Command or Action
Purpose