Installing a Power-Supply Module—Installation d'un module d'alimentation
Note
Use the appropriate terminal screws, depending on whether you are installing a high-voltage (AC or DC)
or a low-voltage (DC) power supply.
Note
If you have a low-voltage DC power-supply module, connect the wires to the terminals labeled
Lo
. If
you have a high-voltage DC power-supply module, connect the wires to the terminals labeled
Hi
.
7.
To connect the AC power:
a. Connect the line wire into the terminal screw labeled
L
and the neutral wire into the terminal screw labeled
N
.
b. Make sure that you cannot see any wire lead. Only wire
with
insulation
should extend from the terminal screw.
Figure 17
Connecting the Wires to the High-Voltage AC Power (PSU1)
To connect the DC power:
a. Connect the positive wire into the terminal screw labeled
+
, and the negative wire into the terminal screw
labeled
–
.
b. Make sure that you cannot see any wire lead. Only wire
with
insulation
should extend from the terminal screw.